Biomarker Lens

Biomarkers · Chemical

Babesia microti IgM

Understand what Babesia microti IgM signals

LOINC codes
88728-1
Commercial laboratory assays
1

We have not added a physiological summary for this biomarker yet. Compare the commercial laboratory assays and population reference ranges below.

Compare commercial laboratory assays for Babesia microti IgM

Check orderable catalog codes, specimen types, fasting requirements, and demographic reference ranges across laboratories.

Babesia microti Antibodies, IgG and IgM

Laboratory
Labcorp
Test code
138315
Specimen
Serum
Fasting
Not stated
LOINC
88728-1
Turnaround
2 - 5 days

Laboratory assay overview

This test is a screening assay for Babesia microti infection or exposure. Serological testing for antibodies to Babesia microti ( B. microti ) can provide evidence to support a diagnosis of babesiosis. Serology should not be used for routine diagnosis of acute babesiosis, as it is difficult to distinguish active from past infection using serology alone. A B. microti IgG antibody titer of greater than or equal to 1:1024 or the presence of B. microti IgM antibody are suggestive of active or recent B. microti infection, while a 4-fold rise in Babesia IgG antibody in sera from the time of acute illness to the time of convalescence confirms the diagnosis. Individuals positive for B. microti antibodies should have confirmatory testing performed by PCR or peripheral blood smear before treatment is considered. The diagnosis of acute babesiosis cannot be confirmed solely by the presence of Babesia antibody in a serum sample collected at a single time point. Babesiosis coinfection should be considered in Lyme disease patients with severe illness, in those whose symptoms are unlikely to be explained by B. burgdorferi infection alone, or in those who do not respond well to standard antibiotic therapy for Lyme disease.

Labcorp test directory, test code 138315

Verify these ranges and sources

We compile every detail above directly from named laboratory directories and published clinical studies. Laboratories calculate standard reference intervals from the statistical distribution of tested populations for a specific assay method and demographic group, rather than setting universal optimal targets.

Always review your personal lab results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.