Heparin-Induced Platelet Antibody with Reflex to SRA, Unfractionated Heparin

Understand what Heparin-Induced Platelet Antibody with Reflex to SRA, Unfractionated Heparin signals

LOINC codes
34701-3, 50727-7, 50728-5, 50733-5, 74005-0, 8251-1
Commercial laboratory assays
1

We have not added a physiological summary for this biomarker yet. Compare the commercial laboratory assays and population reference ranges below.

Compare commercial laboratory assays for Heparin-Induced Platelet Antibody with Reflex to SRA, Unfractionated Heparin

Check orderable catalog codes, specimen types, fasting requirements, and demographic reference ranges across laboratories.

Heparin-Induced Platelet Antibody with Reflex to SRA, Unfractionated Heparin

Laboratory
Quest Diagnostics
Test code
15334
Specimen
Serum
Fasting
Not stated
LOINC
34701-3, 50727-7, 50728-5, 50733-5, 74005-0, 8251-1

Laboratory assay overview

Diagnosis of Heparin Induced Thrombocytopenia is based on clinical criteria, but serological confirmation is often necessary. The ELISA assay measures the Platelet Factor 4/Heparin Complex to IgG. When the ELISA test is positive, testing by Serotonin Release Assay (a platelet activation assay) is more predictive of thrombocytopenia and thrombosis. Note: Patients should not be on ticagrelor (Brilinta) as this may result in a false negative serotonin release assay.

Quest Diagnostics population reference ranges

Quest Diagnostics calculates these statistical intervals for this specific assay and demographic group, not as universal optimal targets.

PopulationRange
Heparin-Induced Platelet AbNegative
OD unitsResults
≤0.300Negative
>0.300 to ≤0.500Weak Positive
>0.500Positive
View complete laboratory reference notes

Heparin-Induced Platelet Ab | Negative Platelet O.D. OD units | Results ≤0.300 | Negative >0.300 to ≤0.500 | Weak Positive >0.500 | Positive

Quest Diagnostics test directory, test code 15334

Verify these ranges and sources

We compile every detail above directly from named laboratory directories and published clinical studies. Laboratories calculate standard reference intervals from the statistical distribution of tested populations for a specific assay method and demographic group, rather than setting universal optimal targets.