ptau217/ABeta 42 Ratio

Understand what ptau217/ABeta 42 Ratio signals

Primary unit
Ratio
LOINC codes
104663-0, 33200-7
Commercial laboratory assays
1

We have not added a physiological summary for this biomarker yet. Compare the commercial laboratory assays and population reference ranges below.

Compare commercial laboratory assays for ptau217/ABeta 42 Ratio

Check orderable catalog codes, specimen types, fasting requirements, and demographic reference ranges across laboratories.

Lumipulse® p-tau217/Beta-Amyloid 42 Ratio, Plasma

Laboratory
Quest Diagnostics
Test code
17970
Specimen
Plasma
Fasting
Not stated
LOINC
104663-0, 33200-7
Turnaround
Set up: Mon-Sat

Laboratory assay overview

AD-Detect™ p-tau217/Beta-Amyloid 1-42 Ratio, Plasma (FDA Cleared) is cleared by the FDA for assessment of patients aged >=50 years with signs or symptoms of cognitive decline. The levels of two proteins, p-tau217 and Beta-amyloid 1-42, are evaluated within the plasma and calculated into an analytical ratio. This ratio is correlated to the presence or absence of amyloid plaques in the patient's brain, which may reduce the need for an amyloid-PET scan.

Quest Diagnostics population reference ranges

Quest Diagnostics calculates these statistical intervals for this specific assay and demographic group, not as universal optimal targets.

PopulationRange
ptau217Not Established
ABeta 42Not Established
ptau217/ABeta 42 Ratio≤0.00370
Lower Risk≤0.00370
Indeterminate Risk0.00371-0.00737
Higher Risk≥0.00738
View complete laboratory reference notes

ptau217 | Not Established ABeta 42 | Not Established ptau217/ABeta 42 Ratio | ≤0.00370 Plasma p-tau217/ABeta 42 ratio Risk Table Lower Risk | ≤0.00370 Indeterminate Risk | 0.00371-0.00737 Higher Risk | ≥0.00738 The Lumipulse G pTau 217/Beta-Amyloid 1-42 Plasma Ratio results must be interpreted in conjunction with other patient clinical information.

Quest Diagnostics test directory, test code 17970

Verify these ranges and sources

We compile every detail above directly from named laboratory directories and published clinical studies. Laboratories calculate standard reference intervals from the statistical distribution of tested populations for a specific assay method and demographic group, rather than setting universal optimal targets.

Always review your personal lab results with a licensed clinician, or track your lab history and health goals in Aumnivida.