Alpha-Fetoprotein and Acetylcholinesterase, Amniotic Fluid with Reflex to HbF

Understand what Alpha-Fetoprotein and Acetylcholinesterase, Amniotic Fluid with Reflex to HbF signals

LOINC codes
1832-5, 29595-6, 30106-9, 49051-6
Commercial laboratory assays
1

We have not added a physiological summary for this biomarker yet. Compare the commercial laboratory assays and population reference ranges below.

Compare commercial laboratory assays for Alpha-Fetoprotein and Acetylcholinesterase, Amniotic Fluid with Reflex to HbF

Check orderable catalog codes, specimen types, fasting requirements, and demographic reference ranges across laboratories.

Alpha-Fetoprotein and Acetylcholinesterase, Amniotic Fluid with Reflex to HbF

Laboratory
Quest Diagnostics
Test code
91615
Specimen
2.4 mL amniotic fluid collected in a sterile leak-proof container
Fasting
Not stated
LOINC
1832-5, 29595-6, 30106-9, 49051-6

Laboratory assay overview

Alpha-fetoprotein (AFP) utility in the early detection of fetal open neural tube defects (NTD) has been widely confirmed. The severity of a neural tube defect can range from moderate, such as spina bifida, to severe and non-life-compatible, such as anencephaly. Acetylcholinesterase(AChE) is an enzyme that hydrolyzes the neurotransmitter acetylcholine. In a fetus with an open neural tube defect, AChE leaks directly into the amniotic fluid from fetal CSF, causing unexpectedly high levels of amniotic fluid AChE. However, a major cause of borderline amniotic fluid AFP elevations and/or false positive AChE results is contamination of the sample with fetal blood. Therefore, reflex testing for the presence of fetal hemoglobin (HbF) should be performed on samples with elevated AFP results, and in particular when acetylcholinesterase is weak positive or not detected at all. It is important to remember that many fetal anomalies, including neural tube defects and ventral wall defects, may also lead to fetal bleeding.

View complete laboratory reference notes

See Laboratory Report

Quest Diagnostics test directory, test code 91615

Verify these ranges and sources

We compile every detail above directly from named laboratory directories and published clinical studies. Laboratories calculate standard reference intervals from the statistical distribution of tested populations for a specific assay method and demographic group, rather than setting universal optimal targets.