Biomarkers · Chemical
11d TXB2/Creat Ratio, Urine
- Primary unit
- pg/mg creat.
- LOINC codes
- 49734-7
- Tests that measure 11d TXB2/Creat Ratio, Urine
- Labcorp 1, Quest Diagnostics 1
Tests
Check the catalog code, specimen, method and preparation for every test that measures 11d TXB2/Creat Ratio, Urine. Select up to five tests to compare them side by side.
Labcorp 1 test
Panels that include this biomarker
AspirinWorks® (11-Dehydro Thromboxane B2) 117320
3 analytes · Urine · Fasting not stated · Turnaround 4 - 9 days
Labcorp catalog pageMethod and collection
- Method
- Enzyme-linked immunoassay AspirinWorks® is a registered trademark of Corgenix Medical Corp, Broomfield, CO.
- Collection
- 1. Instruct the patient to collect at least 10 mL of urine in the urine collection cup. 2. Transfer at least 5 mL of urine into a BD C&S Vacutainer® tube or BD UAP Vacutainer® tube as soon as possible after collection. 3. Cap and mix by gentle inversion. 4. Transfer the contents of the BD C&S Vacutainer® tube or BD UAP Vacutainer® tube to a PP transpack frozen purple tube. Apply appropriate screw cap and freeze immediately. Maintain frozen during transport.
- Reference notes
- Result less or equal to 1500 pg 11dhTxB2 per mg creatinine in a patient on aspirin therapy is consistent with a healthy population responsive to aspirin. If the patient is not on chronic aspirin therapy, the patient may have taken an as−needed aspirin or another aspirin−like platelet suppressing agent, such as omega-3 fatty acids or green tea extract. If the patient is on aspirin therapy, a urinary level above 1500 pg 11dhTxB2/mg creatinine suggests an inadequate response to aspirin. This result is in the range of response that would be expected in an individual not on aspirin therapy. A limitation of this assay for determining aspirin response is extra-platelet sources of TXA2 (e.g., monocytes, macrophages). Unlike platelets, monocytes and macrophages can synthesize new cyclooxygenase following its inhibition by aspirin. This likely contributes significantly to the pool of TXA2 and therefore to the pool of metabolites such as 11dhTxB2, especially in those individuals with a high monocyte/macrophage burden.
Quest Diagnostics 1 test
Panels that include this biomarker
AspirinWorks® 11-Dehydrothromboxane B2 (11-dhTXB2) with Creatinine 16174
3 analytes · Urine · Fasting not stated · Turnaround Set up: Mon-Fri
Quest Diagnostics catalog pageMethod and collection
- Method
- Calculation (CALC) • Enzymatic • Immunoassay (IA)
- Collection
- Recommend using BD C&S Vacutainer tube for collection (Quest Supply #141974). If urine is not collected in the preferred or alternative specimen tubes, it must be poured off into these tubes within 4 hours of collection. It is not recommended to test individuals suffering from urinary tract infections, severe liver disease, or end stage renal disease. Limitations: Test results may be affected by the ingestion of alcohol, green tea extract, chocolate, omega-3 fatty acids, ibuprofen, statins, or COX-2 inhibitors. Testing should not be performed on individuals suffering from urinary tract infections, severe liver disease or end stage renal disease. It is not known how treatment with oral anticoagulants, glycoprotein llb/llla inhibitors, clopidogrel, or heparin will affect test results. Additional Information: It is important to interpret the results with regard to patient history and lifestyle, in particular medications and supplements, as well as other risk factors. The test should not be used to measure return of platelet function after discontinuation of aspirin therapy.
- Reference notes
- See Laboratory Report
0 of 5 tests selected
Pick one moreSources
1 test: codes, specimens, methods, preparation and reference intervals.
Quest Diagnostics test catalog
1 test: codes, specimens, methods, preparation and reference intervals.
LOINC 49734-7
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for 11d TXB2/Creat Ratio, Urine
Registered studies that measure 11d TXB2/Creat Ratio, Urine, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.