Biomarkers · Chemical
ADAMTS13 Activity
- Primary unit
- %
- LOINC codes
- 53622-7
- Tests that measure ADAMTS13 Activity
- Labcorp 3, Quest Diagnostics 1
Ranges
Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ
Quest Diagnostics, ADAMTS13 Activity with Reflex to Inhibitor 14532
| Population | Interval |
|---|---|
| ADAMTS13 Activity | 0.68-1.63 IU/mL |
| ADAMTS13 Inhibitor | <0.4 BEU |
Tests
Check the catalog code, specimen, method and preparation for every test that measures ADAMTS13 Activity. Select up to five tests to compare them side by side.
Labcorp 3 tests
Single-analyte tests
ADAMTS13 Activity 117913
Plasma · Fasting not stated · Turnaround 1 - 2 days
Labcorp catalog pageMethod and collection
- Method
- In Labcorp’s liquid chromatography‐tandem mass spectrometry (LC/MS-MS) assay, ADAMTS13 activity is determined by measuring the cleavage of a synthetic polypeptide substrate (referred to as vWF73) added to plasma samples.6 The amino acid sequence of vWF73 corresponds to amino acid residues 1596 through 1668 of mature von Willebrand Factor (vWF) and, thereby, possesses the tyrosine‐methionine cleavage site and exosite necessary to undergo specific cleavage by plasma ADAMTS13.7 Using LC/MS-MS, cleavage of vWF73 is determined directly by measuring a specific proteolytic product of vWF73 whose quantity is directly proportional to the activity of ADAMTS13 in plasma. The LC/MS-MS activity assay is traceable to the WHO 1st International Standard for ADAMTS138 to ensure accurate measurements and offers several advantages relative to comparable fluorescence‐based assays.
- Collection
- Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Serum gel-barrier tubes and serum tubes with clot initiators should aslo be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). The specimen should be frozen immediately and maintained frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . Please see Shipping Procedure for Priority ADAMTS13 Activity for information on direct shipping procedures.
ADAMTS13 Activity Reflex Profile 117921
Plasma · Fasting not stated · Turnaround 2 - 4 days
Labcorp catalog pageMethod and collection
- Method
- In Labcorp’s liquid chromatography‐tandem mass spectrometry (LC/MS-MS) assay, ADAMTS13 activity is determined by measuring the cleavage of a synthetic polypeptide substrate (referred to as vWF73) added to plasma samples.6 The amino acid sequence of vWF73 corresponds to amino acid residues 1596 through 1668 of mature von Willebrand Factor (vWF) and, thereby, possesses the tyrosine‐methionine cleavage site and exosite necessary to undergo specific cleavage by plasma ADAMTS13.7 Using LC/MS-MS, cleavage of vWF73 is determined directly by measuring a specific proteolytic product of vWF73 whose quantity is directly proportional to the activity of ADAMTS13 in plasma. The LC/MS-MS activity assay is traceable to the WHO 1st International Standard for ADAMTS138 to ensure accurate measurements and offers several advantages relative to comparable fluorescence‐based assays.
- Collection
- Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tubes. Serum gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and (using a transfer pipette) carefully remove two-thirds of the plasma without disturbing the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). The specimen should be frozen immediately and maintained frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
Panels that include this biomarker
COVID-19 Induced Thrombotic Microangiopathy Profile 164044
6 analytes · Serum · Fasting not stated · Turnaround 2 - 4 days
Labcorp catalog pageMethod and collection
- Method
- See individual test components.
- Collection
- Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze plasma within four hours of blood collection and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit seperate frozen specimens for each test requested.
Quest Diagnostics 1 test
Single-analyte tests
ADAMTS13 Activity with Reflex to Inhibitor 14532
Plasma · Fasting not stated · Turnaround Set up: Sun-Thurs
Quest Diagnostics catalog pageMethod and collection
- Method
- Immunoassay (IA)
- Collection
- Please submit a separate, frozen vial for each special coagulation assay ordered. Draw blood in a light blue-top tube containing 3.2% sodium citrate, mix gently by inverting 3-4 times. Centrifuge 15 minutes at 1500 g within one hour of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Freeze immediately and transport on dry ice.
0 of 5 tests selected
Pick one moreSources
Check the guidelines, studies and lab catalogs behind every range and link on this page. Open a source to see each claim it backs.
Lab catalogs
Labcorp test menu
Labcorp
Test catalog: 3 tests, with codes, specimens, methods and reference intervals
Quest Diagnostics test menu
Quest Diagnostics
Test catalog: 1 tests, with codes, specimens, methods and reference intervals
Codes and registries
LOINC 53622-7
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for ADAMTS13 Activity
Registered studies that measure ADAMTS13 Activity, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.