Biomarker Lens

Common biomarkers

  • Hemoglobin
  • Glucose
  • ALT
  • Apolipoprotein B
  • C-Reactive Protein, Cardiac
  • Ferritin
  • Alb/Creat Ratio, Urine
  • Alkaline Phosphatase
  • FSH
  • T4,Free(Direct)

Biomarkers · Chemical

Ammonia, Plasma

An ammonia levels test measures the amount of ammonia in a sample of your blood. Ammonia is also called NH3.

Ammonia Levels, MedlinePlus, National Library of Medicine

Primary unit
ug/dL
LOINC codes
16362-6, 22763-7
Tests that measure Ammonia, Plasma
Labcorp 1, Quest Diagnostics 1

Tests

Check the catalog code, specimen, method and preparation for every test that measures Ammonia, Plasma. Select up to five tests to compare them side by side.

Labcorp 1 test

Single-analyte tests

  • Ammonia, Plasma 007054

    Plasma · Fasting not stated · Turnaround 1 - 2 days

    Method and collection
    Method
    Enzymatic
    Preparation
    Patient should be fasting 12 to 14 hours to avoid lipemia, which interferes with the test.
    Collection
    Tube must be filled completely and kept tightly stoppered at all times. Mix well. Specimen must be placed on ice immediately. Separate plasma from cells within 15 minutes of collection. Patient should not clench fist. Transfer specimen to a plastic transport tube before freezing. Avoid contamination of samples by ammonia from smoking or traffic in the laboratory or patient's room, glassware, or water. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested .
    Reference notes
    See table. Age Male (µg/dL) Female (µg/dL) 0 to 30 d Not established Not established 1 to 6 m 42–137 42–137 7 m to 1 y 34–108 34–108 2 to 12 y 33–97 33–97 13 to 30 y 36–136 29–112 31 to 40 y 40–160 30–130 41 to 50 y 40–200 31–155 51 to 70 y 40–200 34–178 71 to 80 y 31–169 31–169 >80 y 28–135 28–135
    Labcorp catalog page

Quest Diagnostics 1 test

Single-analyte tests

  • Ammonia, Plasma 5509

    Plasma · Fasting not stated · Turnaround Set up: Mon-Fri; Report available: 5 days

    Method and collection
    Method
    Enzymatic
    Collection
    Collect blood from stasis-free vein of patient (e.g., no tourniquet). Patient should not clench fist during collection, as muscular exertion often increases venous ammonia levels. Patient should avoid smoking prior to phlebotomy since smoking increases plasma ammonia levels. Tubes should be filled completely and kept tightly stoppered at all times. Place immediately on ice. Separate plasma from cells within 15 minutes and freeze plasma immediately.
    Reference notes
    ≤72 umol/L
    Quest Diagnostics catalog page

0 of 5 tests selected

Pick one more

Sources

Verify these ranges and sources

We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.

Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.