Biomarker Lens

Common biomarkers

  • Hemoglobin
  • Glucose
  • ALT
  • Apolipoprotein B
  • C-Reactive Protein, Cardiac
  • Ferritin
  • Alb/Creat Ratio, Urine
  • Alkaline Phosphatase
  • FSH
  • T4,Free(Direct)

Biomarkers · Chemical

Angiotensin II

Primary unit
pg/mL
LOINC codes
1860-6
Tests that measure Angiotensin II
Labcorp 1, Quest Diagnostics 1

Tests

Check the catalog code, specimen, method and preparation for every test that measures Angiotensin II. Select up to five tests to compare them side by side.

Labcorp 1 test

Single-analyte tests

  • Angiotensin II 002180

    Plasma · Fasting not stated · Turnaround 4 – 14 days

    Method and collection
    Method
    Radioimmunoassay (RIA)
    Preparation
    Patient must not have received radioactive substances 24 hours prior to test. Patient should be fasting.
    Collection
    Trasylol® kits may be ordered through the PeopleSoft system (LabCorp N° 33328). Using a chilled 6-mL lavender-top (EDTA) tube taken from the kit, collect a whole blood specimen. Mix the specimen several times by inverting the EDTA collection tube. After removing the cap from the EDTA draw tube, take one of the sterile, Beral pipettes (from under the gray foam), and add 0.25 mL Trasylol® to the EDTA tube. Recap the EDTA tube and invert several times to mix well. Centrifuge the EDTA tube to separate the plasma from the cells, and immediately transfer the plasma into one of the brown screw-cap transfer tubes provided in the kit. There should be a "Trasylol® Added" label affixed to the brown transport tubes. Cap and freeze the labeled transport tube containing the EDTA plasma with Trasylol® added. To avoid delays in turnaround time when requesting multiple test on frozen samples, please submit separate frozen specimens for each test requested.
    Labcorp catalog page

Quest Diagnostics 1 test

Single-analyte tests

  • Angiotensin II 36718

    Plasma · Fasting not stated · Turnaround Set up: Tues (p.m.); Report available: 10 days

    Method and collection
    Method
    Radioimmunoassay (RIA)
    Reference notes
    ≤52 ng/L
    Quest Diagnostics catalog page

0 of 5 tests selected

Pick one more

Sources

Verify these ranges and sources

We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.

Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.