Biomarkers · Chemical
Anti-MPO Antibodies
- Primary unit
- units
- LOINC codes
- 46266-3
- Tests that measure Anti-MPO Antibodies
- Quest Diagnostics 7, Labcorp 3
Ranges
Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ
Quest Diagnostics, Myeloperoxidase Antibody (MPO) 8796
| Population | Interval |
|---|---|
| <1.0 AI | No antibody detected |
| ≥1.0 AI | Antibody detected |
Tests
Check the catalog code, specimen, method and preparation for every test that measures Anti-MPO Antibodies. Select up to five tests to compare them side by side.
Quest Diagnostics 7 tests
Single-analyte tests
Myeloperoxidase Antibody (MPO) 8796
Serum · Fasting not stated · Turnaround Set up: Tues, Fri; Report available: 5 days
Quest Diagnostics catalog pageMethod and collection
- Method
- Immunoassay (IA)
Panels that include this biomarker
ANCA Screen with MPO and PR3, with Reflex to ANCA Titer 70159
2 analytes · Serum · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Immunoassay (IA)
- Reference notes
- ANCA Screen Negative P-ANCA Titer <1:20 C-ANCA Titer <1:20 Atypical P-ANCA Titer <1:20 Myeloperoxidase Antibody <1.0 AI No antibody detected ≥1.0 AI Antibody detected Proteinase-3 Antibody <1.0 AI No antibody detected ≥1.0 AI Antibody detected
ANCA Vasculitides 36733
2 analytes · Serum · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Immunoassay (IA)
- Reference notes
- Myeloperoxidase Antibody <1.0 AI No antibody detected ≥1.0 AI Antibody detected Proteinase-3 Antibody <1.0 AI No antibody detected ≥1.0 AI Antibody detected
Inflammatory Bowel Disease Differentiation Panel 16503
3 analytes · Serum · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Immunoassay (IA)
- Reference notes
- ANCA Screen Negative P-ANCA Titer <1:20 C-ANCA Titer <1:20 Atypical P-ANCA Titer <1:20 Myeloperoxidase Antibody <1.0 AI No antibody detected ≥1.0 AI Antibody detected Proteinase-3 Antibody <1.0 AI No antibody detected ≥1.0 AI Antibody detected Saccharomyces cerevisiae Ab (IgG) ≤20.0 U Negative 20.1-29.9 U Equivocal ≥30.0 U Positive Saccharomyces cerevisiae Ab (IgA) ≤20.0 U Negative 20.1-24.9 U Equivocal ≥25.0 U Positive
Lung Hemorrhage and Nephritis Panel 15971
3 analytes · Serum · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Immunoassay (IA)
- Collection
- Avoid hemolysis
- Reference notes
- Glomerular Basement Membrane Antibody (IgG) <1.0 AI No antibody detected ≥1.0 AI Antibody detected Proteinase-3 Antibody <1.0 AI No antibody detected ≥1.0 AI Antibody detected Myeloperoxidase Antibody <1.0 AI No antibody detected ≥1.0 AI Antibody detected
Sensory Neuropathy Complete Antibody Panel 15977
13 analytes · Serum · Fasting required
Quest Diagnostics catalog pageMethod and collection
- Method
- Immunoassay (IA) • Immunotyping • Immunofixation
- Preparation
- Overnight fasting is required
- Collection
- See individual tests. Multiple tubes required for testing. Cryoglobulin Screen and reflex: 3 mL serum required: 2 mL minimum. Since multiple tubes are needed for this panel, designate one tube exclusively for cryoglobulin and treat it differently from the other tubes collected. Allow blood in the tube designated for cryoglobulin to clot for one (1) hour in a 37° C water bath, incubator, heat block, or heel warmer. After clotting, centrifuge the specimen as quickly as possible. It is not necessary to use a warm centrifuge but do not use a refrigerated one. Decant all of the cryoglobulin serum into one transport vial (do not aliquot any of the cryoglobulin serum into any other tube). Transport at room temperature. Note: If the sample is not kept at 37° C during clotting, the cryoglobulin, if present, can precipitate during centrifugation and be lost in the clot resulting in a false negative result.
- Reference notes
- See individual tests
Labcorp 3 tests
Single-analyte tests
Antimyeloperoxidase (MPO) Antibodies 163059
Serum · Fasting not stated · Turnaround 2 - 4 days
Labcorp catalog pageMethod and collection
- Method
- Fluoroenzymeimmunoassay EliA
- Reference notes
- 0.0–5.0 U/mL Negative: <3.5 Equivocal: 3.5 - 5.0 Positive: >5.0
Panels that include this biomarker
Antineutrophil Cytoplasmic Antibody (ANCA) Profile 163061
5 analytes · Serum · Fasting not stated · Turnaround 4 - 7 days
Labcorp catalog pageMethod and collection
- Method
- ANCA: Indirect fluorescent antibody (IFA) MPO and PR3: Fluoroenzyme Immunoassay EliA
Glomerulonephritis (GNP) Profile (RDL) 520194
8 analytes · Serum · Fasting not stated · Turnaround 10 - 12 days
Labcorp catalog pageMethod and collection
- Method
- See individual test components.
- Collection
- Separate serum from cells within one hour of collection. Transfer to a plastic transport tube before shipping. To avoid delays in turnaround time when requesting multiple tests on frozen samples , please submit separate frozen specimens for each test requested.
0 of 5 tests selected
Pick one moreSources
3 tests: codes, specimens, methods, preparation and reference intervals.
Quest Diagnostics test catalog
7 tests: codes, specimens, methods, preparation and reference intervals.
LOINC 46266-3
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for Anti-MPO Antibodies
Registered studies that measure Anti-MPO Antibodies, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.