Biomarkers · Chemical
Beta-2 Glycoprotein I Ab, IgG
- Primary unit
- GPI IgG units
- LOINC codes
- 16135-6
- Tests that measure Beta-2 Glycoprotein I Ab, IgG
- Labcorp 7, Quest Diagnostics 3
Ranges
Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ
Quest Diagnostics, Beta-2-Glycoprotein I Antibody (IgG) with Reflex to B2GPI-Domain 1 12163
| Population | Interval |
|---|---|
| Value | Interpretation |
| <20.0 U/mL | Antibody not detected |
| ≥20.0 U/mL | Antibody detected |
Quest Diagnostics, Beta-2-Glycoprotein I Antibody (IgG) 36554
| Population | Interval |
|---|---|
| Value | Interpretation |
| <20 U/mL | Antibody not detected |
| ≥20 U/mL | Antibody detected |
Tests
Check the catalog code, specimen, method and preparation for every test that measures Beta-2 Glycoprotein I Ab, IgG. Select up to five tests to compare them side by side.
Labcorp 7 tests
Single-analyte tests
β2-Glycoprotein 1 Antibodies, IgG 163882
Serum · Fasting not stated · Turnaround 2 - 4 days
Labcorp catalog pageMethod and collection
- Method
- Thermo Fisher EliA™ automated FEIA-based autoantibody test
- Reference notes
- β2-Glycoprotein 1 Antibodies, IgG: 0.0–16.2 EliA U/mL
Panels that include this biomarker
β2-Glycoprotein 1 Antibodies, IgG, IgM 163002
2 analytes · Serum · Fasting not stated · Turnaround 2 - 4 days
Labcorp catalog pageMethod and collection
- Method
- Thermo Fisher EliA™ automated FEIA-based autoantibody test
- Reference notes
- β2-Glycoprotein 1 Antibodies, IgG: 0.0–16.2 EliA U/mL β2-Glycoprotein 1 Antibodies, IgM: 0.0–8.5 EliA U/mL
β2-Glycoprotein 1 Antibodies, IgA, IgG, IgM 163915
3 analytes · Serum · Fasting not stated · Turnaround 2 - 4 days
Labcorp catalog pageMethod and collection
- Method
- Thermo Fisher EliA™ automated FEIA-based autoantibody test
- Reference notes
- β2-Glycoprotein 1 Antibodies, IgG: 0.0–16.2 EliA U/mL β2-Glycoprotein 1 Antibodies, IgM: 0.0–8.5 EliA U/mL β2-Glycoprotein 1 Antibodies, IgA: 0.0–9.5 EliA U/mL
Lupus Prognostic Profile 520555
9 analytes · Serum · Fasting not stated · Turnaround 7 - 10 days
Labcorp catalog pageMethod and collection
- Method
- ELISA
- Collection
- Separate serum from cells within one hour of collection. Transfer to a plastic transport tube before shipping.
Thrombotic Risk, Acquired 117145
11 analytes · Serum · Fasting not stated · Turnaround 3 - 7 days
Labcorp catalog pageMethod and collection
- Method
- See individual tests.
- Preparation
- Do not draw from an arm with a heparin lock or heparinized catheter.
- Collection
- Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anti-coagulant with the blood. A discard tube is not required prior to collection of coagulation samples except when using a winged blood collection device (i.e., "butterfly"), in which case a discard tube should be used.4,5 When non-citrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap and recentifuge for 10 minutes. Use a second plastic pipette to remove plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. It is important to centrifuge blood samples for plasma collection immediately after collection to separate the plasma from the blood cells. If immediate centrifugation is not possible, collected blood specimens should be kept on ice and centrifuged within an hour. Serum: If a red-top tube is used, transfer separate serum to a plastic transport tube. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Antiphospholipid Syndrome (APS) Assessment 164535
14 analytes · Serum · Fasting not stated · Turnaround 4 - 6 days
Labcorp catalog pageMethod and collection
- Method
- Clot-based assays for lupus anticoagulants and enzyme-linked immunoassays (ELISAs) for antiphospholipid antibodies
- Preparation
- Do not draw from an arm with a heparin lock or heparinized catheter.
- Collection
- Plasma: Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.26 Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio.27,28 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anti-coagulant with the blood. A discard tube is not required prior to collection of coagulation samples except when using a winged blood collection device (i.e., "butterfly"), in which case a discard tube should be used.29,30 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap and recentifuge for 10 minutes. Use a second plastic pipette to remove plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . It is important to centrifuge blood samples for plasma collection immediately after collection to separate the plasma from the blood cells. If immediate centrifugation is not possible, collected blood specimens should be kept on ice and centrifuged within an hour. Serum: If a red-top tube is used, transfer separate serum to a plastic transport tube. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Quest Diagnostics 3 tests
Single-analyte tests
Beta-2-Glycoprotein I Antibody (IgG) 36554
Plasma · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Immunoassay (IA)
- Collection
- Plasma: Centrifuge light blue-top tube for 15 minutes at approximately 1500 g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial. Plasma must be free of platelets (<10,000/mcL).
Beta-2-Glycoprotein I Antibody (IgG) with Reflex to B2GPI-Domain 1 12163
Plasma · Fasting not stated · Turnaround Set up: B2GPI: Mon-Sat, Domain: Tues
Quest Diagnostics catalog pageMethod and collection
- Method
- Immunoassay (IA)
- Collection
- Plasma (preferred): Centrifuge light blue-top tube 15 minutes at approximately 1500 g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial. Plasma must be free of platelets (<10,000/mcL). Serum: Allow blood to clot (10-15 minutes) at room temperature. Centrifuge to separate serum. Pour off serum and refrigerate as soon as possible.
Panels that include this biomarker
Beta-2-Glycoprotein I Antibodies (IgG, IgA, IgM) 30340
3 analytes · Plasma · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Immunoassay (IA)
- Collection
- Plasma: Centrifuge light blue-top tube 15 minutes at approximately 1500 g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial. Plasma must be free of platelets (<10,000/mcL).
- Reference notes
- B2-Glycoprotein I (IgG) Ab <20 U/mL | Antibody not detected ≥20 U/mL | Antibody detected B2-Glycoprotein I (IgA) Ab <20 U/mL | Antibody not detected ≥20 U/mL | Antibody detected B2-Glycoprotein I (IgM) Ab <20 U/mL | Antibody not detected ≥20 U/mL | Antibody detected
0 of 5 tests selected
Pick one moreSources
7 tests: codes, specimens, methods, preparation and reference intervals.
Quest Diagnostics test catalog
3 tests: codes, specimens, methods, preparation and reference intervals.
LOINC 16135-6
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for Beta-2 Glycoprotein I Ab, IgG
Registered studies that measure Beta-2 Glycoprotein I Ab, IgG, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.