Biomarker Lens

Common biomarkers

  • Hemoglobin
  • Glucose
  • ALT
  • Apolipoprotein B
  • C-Reactive Protein, Cardiac
  • Ferritin
  • Alb/Creat Ratio, Urine
  • Alkaline Phosphatase
  • FSH
  • T4,Free(Direct)

Biomarkers · Chemical

Beta-2 Glycoprotein I Ab, IgG

Primary unit
GPI IgG units
LOINC codes
16135-6
Tests that measure Beta-2 Glycoprotein I Ab, IgG
Labcorp 7, Quest Diagnostics 3

Ranges

Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ

Quest Diagnostics, Beta-2-Glycoprotein I Antibody (IgG) with Reflex to B2GPI-Domain 1 12163

PopulationInterval
ValueInterpretation
<20.0 U/mLAntibody not detected
≥20.0 U/mLAntibody detected

Quest Diagnostics test catalog, 12163

Quest Diagnostics, Beta-2-Glycoprotein I Antibody (IgG) 36554

PopulationInterval
ValueInterpretation
<20 U/mLAntibody not detected
≥20 U/mLAntibody detected

Quest Diagnostics test catalog, 36554

Tests

Check the catalog code, specimen, method and preparation for every test that measures Beta-2 Glycoprotein I Ab, IgG. Select up to five tests to compare them side by side.

Labcorp 7 tests

Single-analyte tests

  • β2-Glycoprotein 1 Antibodies, IgG 163882

    Serum · Fasting not stated · Turnaround 2 - 4 days

    Method and collection
    Method
    Thermo Fisher EliA™ automated FEIA-based autoantibody test
    Reference notes
    β2-Glycoprotein 1 Antibodies, IgG: 0.0–16.2 EliA U/mL
    Labcorp catalog page

Panels that include this biomarker

  • β2-Glycoprotein 1 Antibodies, IgG, IgM 163002

    2 analytes · Serum · Fasting not stated · Turnaround 2 - 4 days

    Method and collection
    Method
    Thermo Fisher EliA™ automated FEIA-based autoantibody test
    Reference notes
    β2-Glycoprotein 1 Antibodies, IgG: 0.0–16.2 EliA U/mL β2-Glycoprotein 1 Antibodies, IgM: 0.0–8.5 EliA U/mL
    Labcorp catalog page
  • β2-Glycoprotein 1 Antibodies, IgA, IgG, IgM 163915

    3 analytes · Serum · Fasting not stated · Turnaround 2 - 4 days

    Method and collection
    Method
    Thermo Fisher EliA™ automated FEIA-based autoantibody test
    Reference notes
    β2-Glycoprotein 1 Antibodies, IgG: 0.0–16.2 EliA U/mL β2-Glycoprotein 1 Antibodies, IgM: 0.0–8.5 EliA U/mL β2-Glycoprotein 1 Antibodies, IgA: 0.0–9.5 EliA U/mL
    Labcorp catalog page
  • Lupus Prognostic Profile 520555

    9 analytes · Serum · Fasting not stated · Turnaround 7 - 10 days

    Method and collection
    Method
    ELISA
    Collection
    Separate serum from cells within one hour of collection. Transfer to a plastic transport tube before shipping.
    Labcorp catalog page
  • Thrombotic Risk, Acquired 117145

    11 analytes · Serum · Fasting not stated · Turnaround 3 - 7 days

    Method and collection
    Method
    See individual tests.
    Preparation
    Do not draw from an arm with a heparin lock or heparinized catheter.
    Collection
    Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anti-coagulant with the blood. A discard tube is not required prior to collection of coagulation samples except when using a winged blood collection device (i.e., "butterfly"), in which case a discard tube should be used.4,5 When non-citrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap and recentifuge for 10 minutes. Use a second plastic pipette to remove plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. It is important to centrifuge blood samples for plasma collection immediately after collection to separate the plasma from the blood cells. If immediate centrifugation is not possible, collected blood specimens should be kept on ice and centrifuged within an hour. Serum: If a red-top tube is used, transfer separate serum to a plastic transport tube. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
    Labcorp catalog page
  • Antiphospholipid Syndrome (APS) Assessment 164535

    14 analytes · Serum · Fasting not stated · Turnaround 4 - 6 days

    Method and collection
    Method
    Clot-based assays for lupus anticoagulants and enzyme-linked immunoassays (ELISAs) for antiphospholipid antibodies
    Preparation
    Do not draw from an arm with a heparin lock or heparinized catheter.
    Collection
    Plasma: Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.26 Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio.27,28 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anti-coagulant with the blood. A discard tube is not required prior to collection of coagulation samples except when using a winged blood collection device (i.e., "butterfly"), in which case a discard tube should be used.29,30 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap and recentifuge for 10 minutes. Use a second plastic pipette to remove plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . It is important to centrifuge blood samples for plasma collection immediately after collection to separate the plasma from the blood cells. If immediate centrifugation is not possible, collected blood specimens should be kept on ice and centrifuged within an hour. Serum: If a red-top tube is used, transfer separate serum to a plastic transport tube. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
    Labcorp catalog page

Quest Diagnostics 3 tests

Single-analyte tests

  • Beta-2-Glycoprotein I Antibody (IgG) 36554

    Plasma · Fasting not stated

    Method and collection
    Method
    Immunoassay (IA)
    Collection
    Plasma: Centrifuge light blue-top tube for 15 minutes at approximately 1500 g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial. Plasma must be free of platelets (<10,000/mcL).
    Quest Diagnostics catalog page
  • Beta-2-Glycoprotein I Antibody (IgG) with Reflex to B2GPI-Domain 1 12163

    Plasma · Fasting not stated · Turnaround Set up: B2GPI: Mon-Sat, Domain: Tues

    Method and collection
    Method
    Immunoassay (IA)
    Collection
    ⁠⁠⁠⁠⁠⁠⁠Plasma (preferred): Centrifuge light blue-top tube 15 minutes at approximately 1500 g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial. Plasma must be free of platelets (<10,000/mcL). Serum: Allow blood to clot (10-15 minutes) at room temperature. Centrifuge to separate serum. Pour off serum and refrigerate as soon as possible.
    Quest Diagnostics catalog page

Panels that include this biomarker

  • Beta-2-Glycoprotein I Antibodies (IgG, IgA, IgM) 30340

    3 analytes · Plasma · Fasting not stated

    Method and collection
    Method
    Immunoassay (IA)
    Collection
    Plasma: Centrifuge light blue-top tube 15 minutes at approximately 1500 g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial. Plasma must be free of platelets (<10,000/mcL).
    Reference notes
    B2-Glycoprotein I (IgG) Ab <20 U/mL | Antibody not detected ≥20 U/mL | Antibody detected B2-Glycoprotein I (IgA) Ab <20 U/mL | Antibody not detected ≥20 U/mL | Antibody detected B2-Glycoprotein I (IgM) Ab <20 U/mL | Antibody not detected ≥20 U/mL | Antibody detected
    Quest Diagnostics catalog page

0 of 5 tests selected

Pick one more

Sources

Verify these ranges and sources

We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.

Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.