Biomarkers · Chemical
C. trachomatis, NAA, Pharyn, Throat
- LOINC codes
- 82306-2
- Tests that measure C. trachomatis, NAA, Pharyn, Throat
- Labcorp 3, Quest Diagnostics 2
Ranges
Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ
Quest Diagnostics, Chlamydia/Neisseria gonorrhoeae RNA, TMA, Throat 70051
| Population | Interval |
|---|---|
| C. trachomatis TMA, Throat | Not detected |
| N. gonorrhoeae TMA, Throat | Not detected |
Tests
Check the catalog code, specimen, method and preparation for every test that measures C. trachomatis, NAA, Pharyn, Throat. Select up to five tests to compare them side by side.
Labcorp 3 tests
Single-analyte tests
Chlamydia trachomatis , Pharyngeal Swab, NAA 188714
Swab · Fasting not stated · Turnaround 2 - 3 days
Labcorp catalog pageMethod and collection
- Method
- Nucleic acid amplification (NAA)
- Collection
- Partially peel open the swab package. Remove the swab. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down or the swab is dropped, use a new Aptima Multitest Swab Specimen Collection Kit. Hold the swab, placing your thumb and forefinger in the middle of the swab shaft covering the score line. Do not hold the swab shaft below the score line. Carefully insert the swab into the throat ensuring contact with bilateral tonsils (if present) and the posterior pharyngeal wall, then withdraw the swab without touching the inside of the cheeks or tongue. While holding the swab in the same hand, unscrew the cap from the tube. Do not spill the contents of the tube. If the contents of the tube are spilled, use a new Aptima Multitest Swab Specimen Collection Kit. Immediately place the swab into the transport tube so that the score line is at the top of the tube. Carefully break the swab shaft at the score line against the side of the tube. Immediately discard the top portion of the swab shaft. Tightly screw the cap onto the tube.
Panels that include this biomarker
Chlamydia/Gonococcus , Pharyngeal Swab, NAA 188698
2 analytes · Swab · Fasting not stated · Turnaround 2 - 3 days
Labcorp catalog pageMethod and collection
- Method
- Nucleic acid amplification (NAA)
- Collection
- Partially peel open the swab package. Remove the swab. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down or the swab is dropped, use a new Aptima Multitest Swab Specimen Collection Kit. Hold the swab, placing your thumb and forefinger in the middle of the swab shaft covering the score line. Do not hold the swab shaft below the score line. Carefully insert the swab into the throat ensuring contact with bilateral tonsils (if present) and the posterior pharyngeal wall, then withdraw the swab without touching the inside of the cheeks or tongue. While holding the swab in the same hand, unscrew the cap from the tube. Do not spill the contents of the tube. If the contents of the tube are spilled, use a new Aptima Multitest Swab Specimen Collection Kit. Immediately place the swab into the transport tube so that the score line is at the top of the tube. Carefully break the swab shaft at the score line against the side of the tube. Immediately discard the top portion of the swab shaft. Tightly screw the cap onto the tube.
PrEP Use Only: Chlamydia/Gonococcus , Pharyngeal Swab, NAA 188710
2 analytes · Swab · Fasting not stated · Turnaround 2 - 3 days
Labcorp catalog pageMethod and collection
- Method
- Nucleic acid amplification (NAA)
- Collection
- Partially peel open the swab package. Remove the swab. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down or the swab is dropped, use a new Aptima Multitest Swab Specimen Collection Kit. Hold the swab, placing your thumb and forefinger in the middle of the swab shaft covering the score line. Do not hold the swab shaft below the score line. Carefully insert the swab into the throat ensuring contact with bilateral tonsils (if present) and the posterior pharyngeal wall, then withdraw the swab without touching the inside of the cheeks or tongue. While holding the swab in the same hand, unscrew the cap from the tube. Do not spill the contents of the tube. If the contents of the tube are spilled, use a new Aptima Multitest Swab Specimen Collection Kit. Immediately place the swab into the transport tube so that the score line is at the top of the tube. Carefully break the swab shaft at the score line against the side of the tube. Immediately discard the top portion of the swab shaft. Tightly screw the cap onto the tube.
Quest Diagnostics 2 tests
Single-analyte tests
Chlamydia trachomatis RNA, TMA, Throat 70048
Swab · Fasting not stated · Turnaround Set up: Mon-Sat (All shifts); Report available: 2-5 days
Quest Diagnostics catalog pageMethod and collection
- Method
- Transcription-Mediated Amplification (TMA)
- Collection
- Use the Aptima Multitest transport tube (orange label). Using a tongue depressor, insert the swab and vigorously rub the tonsils and the posterior pharynx. Carefully remove the swab without touching any area of the mouth. Remove the cap from the swab specimen transport tube and immediately place the swab into the transport tube. Carefully break the swab shaft at the score line. Re-cap the swab specimen transport tube tightly, label and ship to the lab. Note: Results from the Aptima Combo 2 Assay should be interpreted in conjunction with other laboratory and clinical data available to the clinician. The Aptima Combo 2 Assay is not intended for the evaluation of suspected sexual abuse or for other medico-legal indications. For a complete list of assay limitations we recommend that you review the manufacturers package insert, https://www.hologic.com/package-inserts/diagnostic-products/aptima-combo-2-assay-ctng
- Reference notes
- Not detected
Panels that include this biomarker
Chlamydia/Neisseria gonorrhoeae RNA, TMA, Throat 70051
2 analytes · Swab · Fasting not stated · Turnaround Set up: Mon-Sat (All shifts); Report available: 2-5 days
Quest Diagnostics catalog pageMethod and collection
- Method
- Transcription-Mediated Amplification (TMA)
- Collection
- Use the Aptima Multitest transport tube (orange label). Using a tongue depressor, insert the swab and vigorously rub the tonsils and the posterior pharynx. Carefully remove the swab without touching any area of the mouth. Remove the cap from the swab specimen transport tube and immediately place the swab into the transport tube. Carefully break the swab shaft at the score line. Re-cap the swab specimen transport tube tightly, label and ship to the lab. Note: Results from the Aptima Combo 2 Assay should be interpreted in conjunction with other laboratory and clinical data available to the clinician. The Aptima Combo 2 Assay is not intended for the evaluation of suspected sexual abuse or for other medico-legal indications. For a complete list of assay limitations we recommend that you review the manufacturers package insert, https://www.hologic.com/package-inserts/diagnostic-products/aptima-combo-2-assay-ctng
0 of 5 tests selected
Pick one moreSources
Check the guidelines, studies and lab catalogs behind every range and link on this page. Open a source to see each claim it backs.
Lab catalogs
Labcorp test menu
Labcorp
Test catalog: 3 tests, with codes, specimens, methods and reference intervals
Quest Diagnostics test menu
Quest Diagnostics
Test catalog: 2 tests, with codes, specimens, methods and reference intervals
Codes and registries
LOINC 82306-2
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for C. trachomatis, NAA, Pharyn, Throat
Registered studies that measure C. trachomatis, NAA, Pharyn, Throat, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.