Biomarker Lens

Common biomarkers

  • Hemoglobin
  • Glucose
  • ALT
  • Apolipoprotein B
  • C-Reactive Protein, Cardiac
  • Ferritin
  • Alb/Creat Ratio, Urine
  • Alkaline Phosphatase
  • FSH
  • T4,Free(Direct)

Biomarkers · Chemical

Chromium, Plasma

Primary unit
ug/L
LOINC codes
5622-6
Tests that measure Chromium, Plasma
Quest Diagnostics 2, Labcorp 1

Ranges

Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ

Labcorp, Chromium, Plasma 071522

AgeMaleFemale
0 to 1 y0.7–3.20.7–3.2
2 to 12 y0.6–3.00.4–2.8
13 to 17 y0.3–2.30.3–2.3
18 to 40 y0.2–1.60.2–1.8
41 to 80 y0.2–4.80.2–4.8
81 to 110 y0.5–3.30.4–3.5

Labcorp test catalog, 071522

Tests

Check the catalog code, specimen, method and preparation for every test that measures Chromium, Plasma. Select up to five tests to compare them side by side.

Quest Diagnostics 2 tests

Single-analyte tests

  • Chromium, Plasma 3484

    Plasma · Fasting not stated · Turnaround Set up: Tues, Thurs, Sat

    Method and collection
    Method
    Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
    Collection
    Draw one (royal blue-top) tube of blood and discard. Draw second (royal blue-top) tube. Centrifuge and pour (do not pipette) the plasma into a metal-free tube.
    Reference notes
    <3.6 mcg/L
    Quest Diagnostics catalog page
  • Chromium, Serum 5248

    Serum · Fasting not stated · Turnaround Set up: Tues, Thurs, Sat

    Method and collection
    Method
    Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
    Collection
    Draw one royal blue-top tube of blood and discard. Draw second royal-blue top tube. Allow to clot in an upright position. Centrifuge and pour (do not pipette) the serum into a metal-free tube. Note: Tests performed on a specimen submitted in a non-trace element tube or non acid-washed/non metal-free container may not accurately reflect the patient's level. If a non-trace element tube/container is received, it will be accepted for testing. However, elevated results shall be reported with a message that a re-submission with a trace element tube/container is recommended.
    Reference notes
    ≤1.4 mcg/L
    Quest Diagnostics catalog page

Labcorp 1 test

Single-analyte tests

  • Chromium, Plasma 071522

    Plasma · Fasting not stated · Turnaround 2 - 5 days

    Method and collection
    Method
    Inductively-coupled plasma/mass spectrometry (ICP/MS)
    Collection
    Separate plasma immediately after the collection, and transfer to a certified metal-free plastic transport tube (PeopleSoft N° 111166) for shipment to the laboratory.
    Labcorp catalog page

0 of 5 tests selected

Pick one more

Sources

Verify these ranges and sources

We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.

Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.