Biomarkers · Chemical
Complement C4a
- Primary unit
- ng/mL
- LOINC codes
- 4501-3
- Tests that measure Complement C4a
- Labcorp 2, Quest Diagnostics 1
Tests
Check the catalog code, specimen, method and preparation for every test that measures Complement C4a. Select up to five tests to compare them side by side.
Labcorp 2 tests
Single-analyte tests
Complement C4a 004330
Plasma · Fasting not stated · Turnaround 4 - 7 days
Labcorp catalog pageMethod and collection
- Method
- Radioimmunoassay (RIA)
- Preparation
- No radioactive isotopes administered within 48 hours prior to venipuncture.
- Collection
- Collect EDTA whole blood sample into a chilled lavender-top tube. Immediately add Futhan preservative as directed in the Futhan collection kit (LabCorp N° 78946). Recap lavender tube and invert several times to mix well. Centrifuge the whole blood specimen to separate the plasma. Transfer the plasma into the plastic screw-cap tube that is included in the collection kit. The specimen must be submitted in this transfer tube, which is labeled with the words "Futhan Added." Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
- Reference notes
- Males: 152.0–1559.4 ng/mL Females: 215.7–2025.9 ng/mL
Panels that include this biomarker
Lupus Monitor Profile 505770
6 analytes · Serum · Fasting not stated · Turnaround 3 - 5 days
Labcorp catalog pageMethod and collection
- Method
- See individual components.
Quest Diagnostics 1 test
Single-analyte tests
Complement Component C4a, Plasma 13555
Plasma · Fasting not stated · Turnaround Set up: Mon, Wed, Sat
Quest Diagnostics catalog pageMethod and collection
- Method
- Enzyme Linked Immunosorbent Assay (ELISA)
- Collection
- Collect whole blood into EDTA (lavender-top) tube. Centrifuge and pour 1-2 mL plasma carefully into protease inhibitor transport tube. (Note gradations on side of tube.) Freeze and transport on dry ice.
- Reference notes
- ≤1028 ng/mL
0 of 5 tests selected
Pick one moreSources
2 tests: codes, specimens, methods, preparation and reference intervals.
Quest Diagnostics test catalog
1 test: codes, specimens, methods, preparation and reference intervals.
LOINC 4501-3
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for Complement C4a
Registered studies that measure Complement C4a, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.