Biomarker Lens

Common biomarkers

  • Hemoglobin
  • Glucose
  • ALT
  • Apolipoprotein B
  • C-Reactive Protein, Cardiac
  • Ferritin
  • Alb/Creat Ratio, Urine
  • Alkaline Phosphatase
  • FSH
  • T4,Free(Direct)

Biomarkers · Chemical

D-Dimer

A D-dimer test looks for D-dimer in blood. D-dimer is a protein fragment (small piece) that's made when a blood clot dissolves in your body.

D-Dimer Test, MedlinePlus, National Library of Medicine

Primary unit
mg/L FEU
LOINC codes
48065-7
Tests that measure D-Dimer
Labcorp 9, Quest Diagnostics 4

Ranges

Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ

Labcorp, D-Dimer 115188

PopulationInterval
870.00−0.87
750.00−0.75
760.00−0.76
770.00−0.77
780.00−0.78
790.00−0.79
800.00−0.80
810.00−0.81
820.00−0.82
830.00−0.83
840.00−0.84
850.00−0.85
860.00−0.86
740.00−0.74
880.00−0.88
890.00−0.89
900.00−0.90
910.00−0.91
920.00−0.92
930.00−0.93
940.00−0.94
950.00−0.95
960.00−0.96
970.00−0.97
980.00−0.98
990.00−0.99
620.00−0.62
500.00−0.50
510.00−0.51
520.00−0.52
530.00−0.53
540.00−0.54
550.00−0.55
560.00−0.56
570.00−0.57
580.00−0.58
590.00−0.59
600.00−0.60
610.00−0.61
Age (Years)Age-Adjusted Cutoff (mg/L FEU)
630.00−0.63
640.00−0.64
650.00−0.65
660.00−0.66
670.00−0.67
680.00−0.68
690.00−0.69
700.00−0.70
710.00−0.71
720.00−0.72
730.00−0.73

Labcorp test catalog, 115188

Tests

Check the catalog code, specimen, method and preparation for every test that measures D-Dimer. Select up to five tests to compare them side by side.

Labcorp 9 tests

Single-analyte tests

  • D-Dimer 115188

    Plasma · Fasting not stated · Turnaround Within 1 day

    Method and collection
    Method
    Immunoturbidimetric assay
    Collection
    Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze plasma immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
    Labcorp catalog page

Panels that include this biomarker

  • Coagulation Activation Profile 117410

    3 analytes · Plasma · Fasting not stated · Turnaround 5 - 8 days

    Method and collection
    Method
    See individual tests.
    Collection
    Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.9 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.10,11 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples.12,13 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested .
    Labcorp catalog page
  • COVID-19 Induced Thrombotic Microangiopathy Profile 164044

    6 analytes · Serum · Fasting not stated · Turnaround 2 - 4 days

    Method and collection
    Method
    See individual test components.
    Collection
    Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze plasma within four hours of blood collection and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit seperate frozen specimens for each test requested.
    Labcorp catalog page
  • Disseminated Intravascular Coagulation (DIC) Profile 116012

    7 analytes · Plasma · Fasting not stated · Turnaround 2 - 3 days

    Method and collection
    Method
    See individual tests.
    Preparation
    None
    Collection
    Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
    Labcorp catalog page
  • Fibrinolysis Profile 117310

    7 analytes · Plasma · Fasting not stated · Turnaround 5 - 8 days

    Method and collection
    Method
    See individual tests.
    Collection
    Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.27 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.28,29 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples.30,31 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Double centrifugation is required for this test to ensure the removal of platelets that contain fibrinolysis factors.32,33 Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
    Labcorp catalog page
  • Disseminated Intravascular Coagulation (DIC) Profile, Comprehensive Plus 117853

    10 analytes · Plasma · Fasting not stated · Turnaround 2 - 3 days

    Method and collection
    Method
    See individual tests.
    Preparation
    None
    Collection
    Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
    Labcorp catalog page

Quest Diagnostics 4 tests

Single-analyte tests

  • D-Dimer, Quantitative 8659

    One full unopened 3.2% sodium citrate (light blue-top) tube · Fasting not stated · Turnaround Set up: Daily (Day shift and Night shift); Report available: 2 days

    Method and collection
    Method
    Immunoturbidimetric
    Collection
    A completely filled tube is necessary because the correct ratio of blood to citrate is critical (9:1). Mix by gentle inversion 3-4 times. Do not uncap.
    Reference notes
    <0.50 mcg/mL FEU
    Quest Diagnostics catalog page

Panels that include this biomarker

  • Post COVID-19 Coagulation Panel 11458

    3 analytes · See individual tests · Fasting not stated

    Method and collection
    Method
    See individual tests
    Reference notes
    See individual tests
    Quest Diagnostics catalog page
  • Thrombotic Marker Panel 11345

    4 analytes · Plasma · Fasting not stated

    Method and collection
    Method
    Enzyme Immunoassay (EIA) • Enzyme Linked Immunosorbent Assay (ELISA) • Hemagglutination (HA) • Immunoturbidimetric
    Collection
    Platelet-poor plasma: Centrifuge light blue-top tube for 15 minutes at approximately 1500 g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial. Plasma must be free of platelets (<10,000/mcL). Freeze immediately and ship on dry ice.
    Reference notes
    See individual tests
    Quest Diagnostics catalog page
  • Fibrinolysis Comprehensive Panel 90923

    9 analytes · Plasma · Fasting required

    Method and collection
    Method
    Chromogenic Assay • Clot Dissolution • Hemagglutination (HA) • Immunoassay (IA) • Latex Agglutination (LA)
    Preparation
    Morning fasting is required. Since lipemia may interfere with clotting endpoint detection, a two-hour fast is recommended.
    Collection
    Please submit a separate, frozen vial for each special coagulation assay ordered. Draw blood in a light blue-top tube containing 3.2% sodium citrate, mix gently by inverting 3-4 times. Centrifuge 15 minutes at 1500 g within one hour of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial(s). Freeze immediately and transport on dry ice. To avoid release of plasminogen activator, do not massage vein vigorously, pump fist excessively or leave tourniquet in place for a prolonged period. Centrifuge within 30 minutes after collection to get platelet-poor plasma and freeze on dry ice. Prohibit exercise prior to drawing sample.
    Reference notes
    See Laboratory Report
    Quest Diagnostics catalog page

0 of 5 tests selected

Pick one more

Sources

Verify these ranges and sources

We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.

Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.