Biomarker Lens

Common biomarkers

  • Hemoglobin
  • Glucose
  • ALT
  • Apolipoprotein B
  • C-Reactive Protein, Cardiac
  • Ferritin
  • Alb/Creat Ratio, Urine
  • Alkaline Phosphatase
  • FSH
  • T4,Free(Direct)

Biomarkers · Chemical

Eosinophil Cationic Protein

Also listed as
eosinophil count, ECP, eos
Primary unit
ug/L
LOINC codes
25638-8
Tests that measure Eosinophil Cationic Protein
Labcorp 1, Quest Diagnostics 1

Tests

Check the catalog code, specimen, method and preparation for every test that measures Eosinophil Cationic Protein. Select up to five tests to compare them side by side.

Labcorp 1 test

Single-analyte tests

  • Eosinophil Cationic Protein (ECP) 004180

    Serum · Fasting not stated · Turnaround 4 - 7 days

    Method and collection
    Method
    ImmunoCAP®
    Collection
    Allow the sample to stand for 60 to 120 minutes to release the ECP in the cells prior to centrifugation. Separate the serum after 60 to 120 minutes and transfer to a plastic transport tube.
    Reference notes
    4−54 μg/L
    Labcorp catalog page

Quest Diagnostics 1 test

Single-analyte tests

  • Eosinophil Cationic Protein (ECP) 37914

    Serum · Fasting not stated · Turnaround Set up: Wed (a.m.)

    Method and collection
    Method
    Fluoroenzyme Immunoassay (UNICAP)
    Collection
    Parameters such as blood collection tube, coagulation time and temperature must be kept within specified limits, since they affect the concentration of released ECP in serum samples. The clotting represents the first incubation in the assay, in which the ECP measured is to be reproducibly released from the eosinophils which have been activated by the inflammation. Collect blood by venipuncture. After collection gently invert the tube 5 times. Release ECP by clotting for 60-120 minutes at room temperature 20-24° C. The temperature must not vary more than + or - 1 degree between sampling occasions to give comparable results. Centrifuge at 1000-1300 x g for 10 minutes at room temperature. Decant serum into a new tube.
    Reference notes
    2-10 mcg/L
    Quest Diagnostics catalog page

0 of 5 tests selected

Pick one more

Sources

Verify these ranges and sources

We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.

Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.