Biomarkers · Chemical
Factor X Activity
- Primary unit
- %
- LOINC codes
- 3218-5
- Tests that measure Factor X Activity
- Labcorp 4, Quest Diagnostics 1
Ranges
Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ
Labcorp, Factor X Activity 086306
| Population | Interval |
|---|---|
| Age | Range |
| 1 d | 46–67% |
| 3 d | 46–75% |
| 1 to 11 m | 77–122% |
| 1 to 5 y | 72–125% |
| 6 to 10 y | 68–125% |
| 11 to 16 y | 53–122% |
| >16 y | 69–131% |
Tests
Check the catalog code, specimen, method and preparation for every test that measures Factor X Activity. Select up to five tests to compare them side by side.
Labcorp 4 tests
Single-analyte tests
Factor X Activity 086306
Plasma · Fasting not stated · Turnaround 2 - 3 days
Labcorp catalog pageMethod and collection
- Method
- The assay consists of the measurement of the clotting time in a system in which all the factors are present in excess except factor X, which is derived from the sample being tested. Testing coagulation factor activities requires that three dilutions be assayed and analyzed to produce a single result.9,10 The slope of the line created by plotting measured factor concentration against sample dilution is evaluated to discern the presence of inhibitors giving rise to nonparallelism.10 Moreover, samples producing results on initial dilution falling outside the analytic measurement range of the assay are tested at additional dilutions to produce reportable results.10
- Preparation
- Ideally, the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa and thrombin inhibitor therapies for about three days prior to testing.
- Collection
- Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Factor X Activity With Inhibitor Reflex 117365
Plasma · Fasting not stated · Turnaround 5 - 7 days
Labcorp catalog pageMethod and collection
- Method
- See individual activity test information for method information. The Bethesda titer measures the amount (titer) of an inhibitor antibody against a specific clotting factor.1 The test uses dilutions of the patient's plasma and determines the amount of antibody needed to neutralize 50% of the factor activity provided by pooled normal plasma with results expressed in Bethesda units (BUs). One Bethesda Unit (BU) is defined as the amount of an inhibitor that will neutralize 50% of one unit of the factor in normal plasma after 120 minutes incubation at 37°C. A higher titer indicates a stronger inhibitor, which can significantly impact treatment. A Bethesda titer assay is not performed when factor level exceeds 40% (i.e., in the absence of measurable factor activity inhibition).
- Preparation
- Ideally, the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa and thrombin inhibitor therapies for about three days prior to testing. Do not draw from an arm with a heparin lock or heparinized catheter.
- Collection
- Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.2 Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio.3,4 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set, a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Panels that include this biomarker
Extrinsic Pathway Coagulation Factor Profile 500041
4 analytes · Plasma · Fasting not stated · Turnaround 2 - 3 days
Labcorp catalog pageMethod and collection
- Method
- See individual tests.
- Preparation
- Do not draw from an arm with a heparin lock or heparinized catheter.
- Collection
- Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Prolonged Protime Profile 117866
7 analytes · Plasma · Fasting not stated · Turnaround 2 - 3 days
Labcorp catalog pageMethod and collection
- Method
- See individual tests.
- Collection
- Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Quest Diagnostics 1 test
Single-analyte tests
Factor X Activity, Clotting 359
Plasma · Fasting not stated · Turnaround Set up: Wed, Fri (a.m.)
Quest Diagnostics catalog pageMethod and collection
- Method
- Photometric Clot Detection
- Collection
- Please submit a separate, frozen vial for each special coagulation assay ordered. Draw blood in a light blue-top tube containing 3.2% sodium citrate, mix gently by inverting 3-4 times. Centrifuge 15 minutes at 1500 g within one hour of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial(s). Freeze immediately and transport on dry ice.
- Reference notes
- 70-150 % normal
0 of 5 tests selected
Pick one moreSources
4 tests: codes, specimens, methods, preparation and reference intervals.
Quest Diagnostics test catalog
1 test: codes, specimens, methods, preparation and reference intervals.
LOINC 3218-5
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for Factor X Activity
Registered studies that measure Factor X Activity, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.