Biomarkers · Chemical
Fibrinogen Activity
- Primary unit
- mg/dL
- LOINC codes
- 3255-7
- Tests that measure Fibrinogen Activity
- Labcorp 8, Quest Diagnostics 3
Ranges
Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ
Labcorp, Fibrinogen Activity 001610
| Population | Interval |
|---|---|
| Age | Reference interval (mg/dL)12-14 |
| 1 d | 192–374 |
| 3 d | 283–401 |
| 1 to 11 m | 82–383 |
| 1 to 5 y | 162–401 |
| 6 to 10 y | 199–409 |
| 11 to 16 y | 212–433 |
| >16 y | 209–464 |
Tests
Check the catalog code, specimen, method and preparation for every test that measures Fibrinogen Activity. Select up to five tests to compare them side by side.
Labcorp 8 tests
Single-analyte tests
Fibrinogen Activity 001610
Plasma · Fasting not stated · Turnaround Within 1 day
Labcorp catalog pageMethod and collection
- Method
- The measurement of fibrinogen activity is based on determination of fibrin polymerization function by the Clauss method.10 This method measures the rate of clot formation after adding a high concentration of thrombin to citrated plasma. The fibrinogen activity is then derived from a standard curve relating the clotting time to plasma standards of known fibrinogen activity.
- Collection
- Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. If testing cannot be completed within 24 hours, specimens should be centrifuged for at least 10 minutes at 1500xg. Plasma should then be transferred to a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintained frozen until tested. Refer to Coagulation Collection Procedures for directions. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Panels that include this biomarker
Fibrinogen Evaluation Profile 336624
4 analytes · Plasma · Fasting not stated · Turnaround 2 - 5 days
Labcorp catalog pageMethod and collection
- Preparation
- Do not draw from an arm with a heparin lock or heparinized catheter.
- Collection
- Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Heart Disease and Stroke Risk Profile 500140
4 analytes · Serum · Fasting not stated · Turnaround 2 - 5 days
Labcorp catalog pageMethod and collection
- Method
- See individual tests.
- Preparation
- Do not draw from an arm with a heparin lock or heparinized catheter.
- Collection
- Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Disseminated Intravascular Coagulation (DIC) Profile 116012
7 analytes · Plasma · Fasting not stated · Turnaround 2 - 3 days
Labcorp catalog pageMethod and collection
- Method
- See individual tests.
- Preparation
- None
- Collection
- Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Prolonged Protime Profile 117866
7 analytes · Plasma · Fasting not stated · Turnaround 2 - 3 days
Labcorp catalog pageMethod and collection
- Method
- See individual tests.
- Collection
- Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Bleeding With Normal aPTT/PT 117700
9 analytes · Plasma · Fasting not stated · Turnaround 4 - 5 days
Labcorp catalog pageMethod and collection
- Method
- See individual tests.
- Preparation
- Do not draw from an arm with a heparin lock or heparinized catheter.
- Collection
- Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tubes. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and (using a plastic transfer pipette) carefully remove two-thirds of the plasma without disturbing the cells. Deliver to a plastic transfer tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a LabCorp PP transpak frozen purple tube with screw cap (LabCorp No. 49482). The specimen should be frozen immediately and maintained frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Quest Diagnostics 3 tests
Single-analyte tests
Fibrinogen Activity, Clauss 461
One full 3.2% sodium citrate (light blue-top) tube · Fasting not stated · Turnaround Set up: Daily (Day shift and Night shift); Report available: 2 days
Quest Diagnostics catalog pageMethod and collection
- Method
- Photometry/Optical, Clauss
- Collection
- Correct ratio of blood to citrate is critical. Do not overfill or underfill collection tube. Mix by inversion 4 times. Do not pool plasma from multiple tubes. For non-heparinized patients, maintain specimen at room temperature. Do not uncap. Non-heparinized patients are stable up to 72 hours at room temperature. Heparinized patients stable for 24 hours at room temperature. If testing cannot be completed within stability limits, centrifuge specimen within 1 hour of collection at 2500-3500 rpm. Transfer plasma to a plastic screw-cap vial and freeze at -20° C immediately.
- Reference notes
- 175-425 mg/dL
Panels that include this biomarker
Post COVID-19 Coagulation Panel 11458
3 analytes · See individual tests · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- See individual tests
- Reference notes
- See individual tests
Fibrinogen Comprehensive Panel without Consultation 14458
5 analytes · Plasma · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Nephelometric • Clot Based Assay • Photometric Clot Detection • Clot Detection • Clauss • Atomic Spectroscopy (AS)
- Collection
- Centrifuge light blue-top tube 15 minutes at approximately 1500 x g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into plastic vials. Plasma must be free of platelets (<10,000/mcL). Freeze immediately and ship on dry ice.
- Reference notes
- See Laboratory Report
0 of 5 tests selected
Pick one moreSources
8 tests: codes, specimens, methods, preparation and reference intervals.
Quest Diagnostics test catalog
3 tests: codes, specimens, methods, preparation and reference intervals.
LOINC 3255-7
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for Fibrinogen Activity
Registered studies that measure Fibrinogen Activity, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.