Biomarkers · Chemical
GlycoMark(R)(1,5 AG)
- Primary unit
- ug/mL
- LOINC codes
- 53835-5
- Tests that measure GlycoMark(R)(1,5 AG)
- Labcorp 3, Quest Diagnostics 1
Ranges
Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ
Quest Diagnostics, 1,5-Anhydroglucitol (1,5-AG), Intermediate Glycemic Control 10378
| Age | Male (mcg/mL) | Female (mcg/mL) |
|---|---|---|
| ≤1 year | Not established | Not established |
| 2-17 years | 15.0-38.0 | 11.2-35.7 |
| ≥18 years | 7.3-36.6 | 7.5-28.4 |
Tests
Check the catalog code, specimen, method and preparation for every test that measures GlycoMark(R)(1,5 AG). Select up to five tests to compare them side by side.
Labcorp 3 tests
Single-analyte tests
GlycoMark® 500115
Serum · Fasting not stated · Turnaround 3 - 5 days
Labcorp catalog pageMethod and collection
- Method
- Enzymatic, colorimetric assay. GlycoMark® is a registered trademark of GlycoMark Inc, New York, NY.
- Collection
- Separate serum or plasma from cells within one hour of collection.
- Reference notes
- • <18 years: Not established • Adult male: 10.7−32.0 μg/mL • Adult female: 6.8−29.3 μg/mL • Glycemic control goal for diabetic patients: >10
Panels that include this biomarker
GlycoMark® and Hb A1c 502226
2 analytes · Serum · Fasting not stated · Turnaround 3 - 10 days
Labcorp catalog pageMethod and collection
- Method
- Roche Tina Quant; enzymatic
- Collection
- Serum or plasma must be separated from cells within 45 minutes of venipuncture. Send serum or plasma in a plastic transport tube.
- Reference notes
- GlycoMark®: • <18 years: Not established • Adult male: 10.7−32.0 μg/mL • Adult female: 6.8−29.3 μg/mL • Glycemic control goal for diabetic patients: >10 Hb A1c (percent): • Normal: <5.7% • Increased risk for diabetes: 5.7% to 6.4% • Ongoing hyperglycemia: >6.4%
Hemoglobin (Hb) A1c With GlycoMark® Reflex 503205
3 analytes · Serum · Fasting not stated · Turnaround 3 - 10 days
Labcorp catalog pageMethod and collection
- Method
- See individual assays. GlycoMark® is a registered trademark of GlycoMark Inc, New York, NY.
- Collection
- Separate serum or plasma from cells within one hour of collection. Ship in plastic transport tube.
- Reference notes
- GlycoMark®: • <18 years: Not established • Adult males: 10.7−32.0 μg/mL • Adult females: 6.8−29.3 μg/mL • Glycemic control goal for diabetic patients: >10 Hemoglobin A1c (percent): • Normal: <5.7 • Increased risk for diabetes: 5.7−6.4 • Ongoing hyperglycemia: >6.4 • Estimated average glucose: − Glycemic control for adults with diabetes: <7.0 (ADA) Note: If A1c results are between 6.0 and 8.0 (including 6.0 and 8.0), GlycoMark® testing is performed. GlycoMark® reflects postprandial glucose spikes from the previous two weeks, whereas A1c reflects average glycemic control during the previous three months.
Quest Diagnostics 1 test
Single-analyte tests
1,5-Anhydroglucitol (1,5-AG), Intermediate Glycemic Control 10378
Serum · Fasting not stated · Turnaround Set up: Sun, Tues, Thurs-Sat
Quest Diagnostics catalog pageMethod and collection
- Method
- Enzymatic
0 of 5 tests selected
Pick one moreSources
3 tests: codes, specimens, methods, preparation and reference intervals.
Quest Diagnostics test catalog
1 test: codes, specimens, methods, preparation and reference intervals.
LOINC 53835-5
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for GlycoMark(R)(1,5 AG)
Registered studies that measure GlycoMark(R)(1,5 AG), on the U.S. National Library of Medicine registry.