Biomarkers · Chemical
hCG,Beta Subunit,Qnt,Serum
- Primary unit
- mIU/mL
- LOINC codes
- 45194-8
- Tests that measure hCG,Beta Subunit,Qnt,Serum
- Labcorp 9
Tests
Check the catalog code, specimen, method and preparation for every test that measures hCG,Beta Subunit,Qnt,Serum. Select up to five tests to compare them side by side.
Labcorp 9 tests
Single-analyte tests
Human Chorionic Gonadotropin (hCG), β-Subunit, Quantitative 004416
Serum · Fasting not stated · Turnaround Within 1 day
Labcorp catalog pageMethod and collection
- Method
- Electrochemiluminescence immunoassay (ECLIA) This assay is performed on the Roche cobas instrument in multiple laboratories throughout Labcorp.
- Collection
- If a red-top tube or plasma is used, transfer separated serum or plasma to a plastic transport tube.
- Reference notes
- See table. Range (mIU/mL) Weeks of pregnancy is defined as completed weeks beginning with the start of the last menstruation phase. Male | 0−3 Female nonpregnant | 0−5 postmenopausal | 0−8 pregnant Weeks Gestation 3 | 6−71 4 | 10−750 5 | 217−7138 6 | 158−31,795 7 | 3697−163,563 8 | 32,065−149,571 9 | 63,803−151,410 10 | 46,509−186,977 12 | 27,832−210,612 14 | 13,950−62,530 15 | 12,039−70,971 16 | 9040−56,451 17 | 8175−55,868 18 | 8099−58,176
Human Chorionic Gonadotropin (hCG), β-Subunit, Quantitative (Serial Monitor) 480038
Specimen not stated · Fasting not stated · Turnaround Within 1 day
Panels that include this biomarker
Testicular Cancer Monitor Profile 485151
2 analytes · Serum · Fasting not stated · Turnaround Within 1 day
Labcorp catalog pageMethod and collection
- Method
- See individual tests.
- Collection
- If a red-top tube is used, transfer separated serum to a plastic transport tube.
PrEP, Female, Injectable Monitor (No HIV RNA) 254951
5 analytes · Serum · Fasting not stated · Turnaround 2 - 3 days (testing performed daily)
Labcorp catalog pageMethod and collection
- Method
- See individual test components.
- Preparation
- Patient should not have urinated for one hour prior to specimen collection.
- Collection
- Serum specimen: Usual blood collection technique. Option 1: Gen-Probe® Aptima® Endocervical or Vaginal Swab Endocervical swab: Remove excess mucus from the cervical os and surrounding mucosa using the cleaning swab (white-shaft swab in the package with red printing). Discard this swab. Insert the specimen collection swab (blue-shaft swab in the package with green printing) into the endocervical canal. Gently rotate the swab clockwise for 10 to 30 seconds in the endocervical canal to ensure adequate sampling. Withdraw the swab carefully; avoid contact with the vaginal mucosa. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of the contents. Recap the swab specimen transport tube tightly. Vaginal swab: Care provider specimen: Collect vaginal fluid sample using the Gen-Probe® Aptima® vaginal swab kit by contacting the swab to the lower third of the vaginal wall and rotating the swab for 10 to 30 seconds to absorb fluid. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Patient self-collection: Partially open the package of the Gen-Probe® Aptima® vaginal swab kit. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima® swab specimen collection kit. Remove the swab. Carefully insert the swab into the vagina about two inches past the introitus and gently rotate the swab for 10 to 30 seconds, making sure the swab touches the walls of the vagina so that moisture is absorbed by the swab. Withdraw the swab without touching the skin. Immediately place the swab into the transport tube, and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Option 2: Urine Specimen: The patient should not have urinated for at least one hour prior to specimen collection. Direct patient to provide a first-catch urine (approximately 20 to 30 mL of the initial urine stream) into a urine collection cup free of any preservatives. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity; lesser volumes may not adequately rinse organisms into the specimen. Female patients should not cleanse the labial area prior to providing the specimen. Add urine to the Aptima® Combo 2 urine collection device. The final volume must be between the two black lines on the device (about 2 mL). PCR test: Centrifuge sample within 24 hours of collection. Transfer serum to a screw-cap polypropylene transport tube. Ship frozen (preferred) or refrigerated.
PrEP, Female, Oral Monitor (No HIV RNA) 254905
5 analytes · Serum · Fasting not stated · Turnaround 2 - 3 days (testing performed daily)
Labcorp catalog pageMethod and collection
- Method
- See individual test components.
- Preparation
- Patient should not have urinated for one hour prior to specimen collection.
- Collection
- Serum specimen: Usual blood collection technique. Option 1: Gen-Probe® Aptima® Endocervical or Vaginal Swab Endocervical swab: Remove excess mucus from the cervical os and surrounding mucosa using the cleaning swab (white-shaft swab in the package with red printing). Discard this swab. Insert the specimen collection swab (blue-shaft swab in the package with green printing) into the endocervical canal. Gently rotate the swab clockwise for 10 to 30 seconds in the endocervical canal to ensure adequate sampling. Withdraw the swab carefully; avoid contact with the vaginal mucosa. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of the contents. Recap the swab specimen transport tube tightly. Vaginal swab: Care provider specimen: Collect vaginal fluid sample using the Gen-Probe® Aptima® vaginal swab kit by contacting the swab to the lower third of the vaginal wall and rotating the swab for 10 to 30 seconds to absorb fluid. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Patient self-collection: Partially open the package of the Gen-Probe® Aptima® vaginal swab kit. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima® swab specimen collection kit. Remove the swab. Carefully insert the swab into the vagina about two inches past the introitus and gently rotate the swab for 10 to 30 seconds, making sure the swab touches the walls of the vagina so that moisture is absorbed by the swab. Withdraw the swab without touching the skin. Immediately place the swab into the transport tube, and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Option 2: Urine Specimen: The patient should not have urinated for at least one hour prior to specimen collection. Direct patient to provide a first-catch urine (approximately 20 to 30 mL of the initial urine stream) into a urine collection cup free of any preservatives. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity; lesser volumes may not adequately rinse organisms into the specimen. Female patients should not cleanse the labial area prior to providing the specimen. Add urine to the Aptima® Combo 2 urine collection device. The final volume must be between the two black lines on the device (about 2 mL). PCR test: Centrifuge sample within 24 hours of collection. Transfer serum to a screw-cap polypropylene transport tube. Ship frozen (preferred) or refrigerated.
PrEP, Female, Injectable Monitor + HIV RNA 254801
7 analytes · Serum · Fasting not stated · Turnaround 2 - 3 days (testing performed daily)
Labcorp catalog pageMethod and collection
- Method
- See individual test components.
- Preparation
- Patient should not have urinated for one hour prior to specimen collection.
- Collection
- Serum specimen: Usual blood collection technique. Option 1: Gen-Probe® Aptima® Endocervical or Vaginal Swab Endocervical swab: Remove excess mucus from the cervical os and surrounding mucosa using the cleaning swab (white-shaft swab in the package with red printing). Discard this swab. Insert the specimen collection swab (blue-shaft swab in the package with green printing) into the endocervical canal. Gently rotate the swab clockwise for 10 to 30 seconds in the endocervical canal to ensure adequate sampling. Withdraw the swab carefully; avoid contact with the vaginal mucosa. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of the contents. Recap the swab specimen transport tube tightly. Vaginal swab: Care provider specimen: Collect vaginal fluid sample using the Gen-Probe® Aptima® vaginal swab kit by contacting the swab to the lower third of the vaginal wall and rotating the swab for 10 to 30 seconds to absorb fluid. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Patient self-collection: Partially open the package of the Gen-Probe® Aptima® vaginal swab kit. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima® swab specimen collection kit. Remove the swab. Carefully insert the swab into the vagina about two inches past the introitus and gently rotate the swab for 10 to 30 seconds, making sure the swab touches the walls of the vagina so that moisture is absorbed by the swab. Withdraw the swab without touching the skin. Immediately place the swab into the transport tube, and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Option 2: Urine Specimen: The patient should not have urinated for at least one hour prior to specimen collection. Direct patient to provide a first-catch urine (approximately 20 to 30 mL of the initial urine stream) into a urine collection cup free of any preservatives. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity; lesser volumes may not adequately rinse organisms into the specimen. Female patients should not cleanse the labial area prior to providing the specimen. Add urine to the Aptima® Combo 2 urine collection device. The final volume must be between the two black lines on the device (about 2 mL). PCR test: Centrifuge sample within 24 hours of collection. Transfer serum to a screw-cap polypropylene transport tube. Ship frozen (preferred) or refrigerated.
PrEP, Female, Oral Monitor + HIV RNA 254880
7 analytes · Serum · Fasting not stated · Turnaround 2 - 3 days (testing performed daily)
Labcorp catalog pageMethod and collection
- Method
- See individual test components.
- Preparation
- Patient should not have urinated for one hour prior to specimen collection.
- Collection
- Serum specimen: Usual blood collection technique. Option 1: Gen-Probe® Aptima® Endocervical or Vaginal Swab Endocervical swab: Remove excess mucus from the cervical os and surrounding mucosa using the cleaning swab (white-shaft swab in the package with red printing). Discard this swab. Insert the specimen collection swab (blue-shaft swab in the package with green printing) into the endocervical canal. Gently rotate the swab clockwise for 10 to 30 seconds in the endocervical canal to ensure adequate sampling. Withdraw the swab carefully; avoid contact with the vaginal mucosa. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of the contents. Recap the swab specimen transport tube tightly. Vaginal swab: Care provider specimen: Collect vaginal fluid sample using the Gen-Probe® Aptima® vaginal swab kit by contacting the swab to the lower third of the vaginal wall and rotating the swab for 10 to 30 seconds to absorb fluid. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Patient self-collection: Partially open the package of the Gen-Probe® Aptima® vaginal swab kit. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima® swab specimen collection kit. Remove the swab. Carefully insert the swab into the vagina about two inches past the introitus and gently rotate the swab for 10 to 30 seconds, making sure the swab touches the walls of the vagina so that moisture is absorbed by the swab. Withdraw the swab without touching the skin. Immediately place the swab into the transport tube, and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Option 2: Urine Specimen: The patient should not have urinated for at least one hour prior to specimen collection. Direct patient to provide a first-catch urine (approximately 20 to 30 mL of the initial urine stream) into a urine collection cup free of any preservatives. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity; lesser volumes may not adequately rinse organisms into the specimen. Female patients should not cleanse the labial area prior to providing the specimen. Add urine to the Aptima® Combo 2 urine collection device. The final volume must be between the two black lines on the device (about 2 mL). PCR test: Centrifuge sample within 24 hours of collection. Transfer serum to a screw-cap polypropylene transport tube. Ship frozen (preferred) or refrigerated.
0 of 5 tests selected
Pick one moreSources
9 tests: codes, specimens, methods, preparation and reference intervals.
LOINC 45194-8
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for hCG,Beta Subunit,Qnt,Serum
Registered studies that measure hCG,Beta Subunit,Qnt,Serum, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.