Biomarker Lens

Common biomarkers

  • Hemoglobin
  • Glucose
  • ALT
  • Apolipoprotein B
  • C-Reactive Protein, Cardiac
  • Ferritin
  • Alb/Creat Ratio, Urine
  • Alkaline Phosphatase
  • FSH
  • T4,Free(Direct)

Biomarkers · Chemical

HIV-1 RNA by PCR

Primary unit
copies/mL
LOINC codes
20447-9
Tests that measure HIV-1 RNA by PCR
Labcorp 21, Quest Diagnostics 6

Ranges

Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ

Quest Diagnostics, Quantitative HIV-1, Real-Time PCR 16290

PopulationInterval
<40copies/mL
<1.60Log copies/mL

Quest Diagnostics test catalog, 16290

Quest Diagnostics, Post-Transplant, HIV-1 RNA, Real-Time PCR, Plasma 18003

PopulationInterval
HIV 1 RNA, QN PCRNot Detected (copies/mL)
HIV 1 RNA, QN PCRNot Detected (Log copies/mL)

Quest Diagnostics test catalog, 18003

Quest Diagnostics, HIV-1 RNA, Quantitative, Real-Time PCR 40085

HIV-1 RNA, QN, PCRNot detectedcopies/mL
HIV-1 RNA, QN, PCRNot detectedLog copies/mL

Quest Diagnostics test catalog, 40085

Quest Diagnostics, HIV-1 RNA, Quantitative Real-Time PCR with Reflex to Coreceptor Tropism,UDS 94016

PopulationInterval
HIV-1 RNA, QN,PCRNot Detected (copies/mL)
HIV-1 RNA, QN, PCRNot Detected (Log copies/mL)

Quest Diagnostics test catalog, 94016

Tests

Check the catalog code, specimen, method and preparation for every test that measures HIV-1 RNA by PCR. Select up to five tests to compare them side by side.

Labcorp 21 tests

Panels that include this biomarker

  • Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) 550420

    2 analytes · Plasma · Fasting not stated · Turnaround 3 - 5 days

    Method and collection
    Method
    Cobas® HIV
    Collection
    Centrifuge sample within 24 hours of collection. Transfer plasma to a screw-cap polypropylene transport tube. Ship frozen (preferred). To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit a separate frozen specimen for each test requested.
    Labcorp catalog page
  • Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to HIV-1 GenoSure PRIme® 550630

    2 analytes · Plasma · Fasting not stated · Turnaround 17 - 25 days

    Method and collection
    Method
    Cobas® AmpliPrep/Cobas® TaqMan® HIV-1 Test, Version 2.0
    Collection
    Collect specimen in three lavender-top (EDTA) tubes or three PPT™ tubes. Do not use green-top (heparin) tubes. Centrifuge specimen within six hours of collection. Transfer plasma to one or more screw-cap polypropylene transport tube(s). Snap-cap or pop-top tubes should be avoided and may result in specimen rejection. Immediately freeze specimen at -20°C. Do not place samples on dry ice until completely frozen. Ship specimens frozen. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
    Labcorp catalog page
  • Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to HIV-1 GenoSure PRIme® or GenoSure Archive® 550920

    2 analytes · Plasma · Fasting not stated · Turnaround 4 - 6 days

    Method and collection
    Method
    Cobas® AmpliPrep/Cobas® TaqMan® HIV-1 Test, Version 2.0 and polymerase chain reaction (PCR) amplification and DNA sequencing
    Collection
    Both frozen plasma and frozen whole blood are required for this profile. Draw three lavender-top (EDTA) tubes. Do not use green-top (heparin) tubes. Plasma: Centrifuge two tubes within six hours of collection. Remove plasma, transfer plasma to screw-cap polypropylene transport tubes (not "pop-top" or "snap-cap"), and freeze. Ship specimen frozen. Whole blood: Do not centrifuge. Freeze tube immediately after draw. Ship specimen frozen. To avoid delays in turnaround time, when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
    Labcorp catalog page
  • Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to HIV-1 GenoSure® MG 550422

    2 analytes · Plasma · Fasting not stated · Turnaround 9 - 16 days

    Method and collection
    Method
    Cobas® AmpliPrep/Cobas® TaqMan® HIV-1 Test, Version 2.0
    Collection
    Collect specimen in three lavender-top (EDTA) tubes or three PPT™ tubes. Do not use green-top (heparin) tubes. Centrifuge specimen within six hours of collection. Transfer plasma to one or more screw-cap polypropylene transport tube(s). Snap-cap or pop-top tubes should be avoided and may result in specimen rejection. Immediately freeze specimen at - 20° C. Do not place samples on dry ice until completely frozen. Ship specimens frozen. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
    Labcorp catalog page
  • Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to HIV-1 PhenoSense GT® Plus Integrase 550711

    2 analytes · Plasma · Fasting not stated · Turnaround 24 days

    Method and collection
    Method
    Cobas® AmpliPrep/Cobas® TaqMan® HIV-1 Test, Version 2.0
    Collection
    Collect specimen in three lavender-top (EDTA) tubes or three PPT™ tubes. Do not use green-top (heparin) tubes. Centrifuge specimen within six hours of collection. Remove plasma, transfer plasma to screw-cap polypropylene transport tubes (not "pop-top" or "snap-cap"), and freeze. Ship frozen (preferred). Do not ship frozen in PPT™. If PPT™ is used to collect plasma, specimen must be transferred to a screw-cap tube prior to freezing to avoid false elevation of low viral load samples. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
    Labcorp catalog page

Quest Diagnostics 6 tests

Single-analyte tests

  • HIV-1 RNA, Quantitative Real-Time PCR with Reflex to Coreceptor Tropism,UDS 94016

    Plasma · Fasting not stated · Turnaround Set up: Mon-Sat

    Method and collection
    Method
    Real-Time Polymerase Chain Reaction
    Collection
    Samples submitted in primary tube will be rejected. Freshly drawn specimens (whole blood) may be stored at 2-25° C for up to 24 hours prior to centrifugation. Separate plasma from cells within 24 hours of collection by centrifugation and immediately transfer to a transport tube. Follow manufacturer's instructions for collection tube handling.
    Quest Diagnostics catalog page
  • HIV-1 RNA, Quantitative, PCR with Reflex to Genotype 34471

    Plasma · Fasting not stated

    Method and collection
    Method
    Real-Time Polymerase Chain Reaction
    Collection
    Samples submitted in primary tube will be rejected. Freshly drawn specimens (whole blood) may be stored at 2-25° C for up to 24 hours prior to centrifugation. Separate plasma from cells within 24 hours of collection by centrifugation and immediately transfer to a transport tube. Follow manufacturer's instructions for collection tube handling.
    Reference notes
    HIV-1 RNA, QN, PCR | Not detected | copies/mL HIV-1 RNA, QN, PCR | Not detected | Log copies/mL HIV-1 Genotype | See Laboratory Report
    Quest Diagnostics catalog page
  • HIV-1 RNA, Quantitative, Real-Time PCR 40085

    Plasma · Fasting not stated · Turnaround Set up: Mon-Fri (a.m.); Report available: 5 days

    Method and collection
    Method
    Real-Time Polymerase Chain Reaction
    Collection
    Do not freeze whole blood or any samples stored in primary tube. Freshly drawn specimens (whole blood) may be stored at 2-25° C for up to 24 hours prior to centrifugation. Separate plasma from cells within 24 hours of collection by centrifugation. If shipping frozen, transfer plasma to a leak-proof transport tube, then freeze prior to shipment. Follow manufacturer's instructions for collection tube handling.
    Quest Diagnostics catalog page
  • HIV-1 RNA, Quantitative, Real-Time PCR, with Reflex to Integrase Genotype 90926

    Plasma · Fasting not stated · Turnaround Set up: Mon-Sat

    Method and collection
    Method
    Real-Time Polymerase Chain Reaction
    Collection
    Samples submitted in primary tube will be rejected. Freshly drawn specimens (whole blood) may be stored at 2-25° C for up to 24 hours prior to centrifugation. Separate plasma from cells within 24 hours of collection by centrifugation and immediately transfer to a transport tube. Follow manufacturer's instructions for collection tube handling.
    Reference notes
    HIV-1 RNA, QN, PCR | Not detected | copies/mL HIV-1 RNA, QN, PCR | Not detected | Log copies/mL
    Quest Diagnostics catalog page
  • Post-Transplant, HIV-1 RNA, Real-Time PCR, Plasma 18003

    Plasma · Fasting not stated · Turnaround Set up: Daily

    Method and collection
    Method
    Real-Time Polymerase Chain Reaction
    Collection
    For Shipper collection please see detailed instructions in Test Resources
    Quest Diagnostics catalog page
  • Quantitative HIV-1, Real-Time PCR 16290

    Plasma · Fasting not stated · Turnaround Set up: Mon-Fri

    Method and collection
    Method
    Real-Time Polymerase Chain Reaction (RT-PCR)
    Collection
    Separate plasma from the cells by centrifugation within 6 hours of collection and transfer plasma to a screw-cap vial and ship frozen.
    Quest Diagnostics catalog page

0 of 5 tests selected

Pick one more

Sources

Verify these ranges and sources

We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.

Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.