Biomarker Lens

Common biomarkers

  • Hemoglobin
  • Glucose
  • ALT
  • Apolipoprotein B
  • C-Reactive Protein, Cardiac
  • Ferritin
  • Alb/Creat Ratio, Urine
  • Alkaline Phosphatase
  • FSH
  • T4,Free(Direct)

Biomarkers · Chemical

HPV 16, Anorectal

LOINC codes
77396-0
Tests that measure HPV 16, Anorectal
Labcorp 1, Quest Diagnostics 1

Tests

Check the catalog code, specimen, method and preparation for every test that measures HPV 16, Anorectal. Select up to five tests to compare them side by side.

Labcorp 1 test

Panels that include this biomarker

  • Human Papillomavirus (HPV) High-risk (Cobas®) With HPV 16 and 18, Rectal Source 508005

    3 analytes · Swab · Fasting not stated · Turnaround 4 - 6 days

    Method and collection
    Method
    Nucleic acid amplification (NAA)
    Collection
    An anal-rectal cytology specimen is collected using a Dacron swab (for example: AMD-Ritmed Company Catalog N° 4001D, LabCorp N° 19762). Moisten the swab in tap water and insert as far as possible into the anal canal. Slowly rotate the swab in one direction with gentle pressure on the walls as the swab is slowly being withdrawn. Care should be taken to ensure the transition zone is sampled. Vigorously rotate the swab in the PreservCyt® solution 10 times while pushing against the wall of the ThinPrep® vial. Swirl the swab vigorously to release additional material. Discard the swab. Tighten the cap on the ThinPrep® container so that the torque line on the cap passes the torque line on the vial.
    Labcorp catalog page

Quest Diagnostics 1 test

Panels that include this biomarker

  • HPV Genotypes 16, 18/45, Anal-Rectal 92807

    2 analytes · Swab · Fasting not stated · Turnaround Set up: Mon, Wed, Fri

    Method and collection
    Method
    Transcription-Mediated Amplification (TMA)
    Collection
    To collect an anal-rectal sample, a wetted, non-lubricated Dacron/Polyester swab is used. The Dacron/Polyester swab is inserted about 3 cm (or until resistance is met) into the anal canal past the anal verge, into the rectal vault. This is done without visualization of the anal canal. Firm lateral pressure is applied to the swab handle as it is rotated and slowly moved in and out. Slowly withdraw swab from the anal canal. Swish the swab vigorously in PreservCyt® fluid in the ThinPrep® vial. Discard the swab. Cap and tighten the ThinPrep® vial. Follow the same procedure if using a brush to collect an anal-rectal sample. Avoid using cotton swab on a wooden stick because the handle may break and splinter during collection. Swab that is grossly contaminated with feces should be discarded and the collection repeated.
    Reference notes
    Not Detected
    Quest Diagnostics catalog page

0 of 5 tests selected

Pick one more

Sources

Verify these ranges and sources

We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.

Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.