Biomarker Lens

Common biomarkers

  • Hemoglobin
  • Glucose
  • ALT
  • Apolipoprotein B
  • C-Reactive Protein, Cardiac
  • Ferritin
  • Alb/Creat Ratio, Urine
  • Alkaline Phosphatase
  • FSH
  • T4,Free(Direct)

Biomarkers · Chemical

Immune Complexes, C1q Binding

Primary unit
ug Eq/mL
LOINC codes
27831-7
Tests that measure Immune Complexes, C1q Binding
Labcorp 2, Quest Diagnostics 1

Tests

Check the catalog code, specimen, method and preparation for every test that measures Immune Complexes, C1q Binding. Select up to five tests to compare them side by side.

Labcorp 2 tests

Single-analyte tests

  • Immune Complexes, C1q Binding 096933

    Serum · Fasting not stated · Turnaround 4 - 8 days

    Method and collection
    Method
    Enzyme immunoassay (EIA)
    Collection
    Separate serum from cells. Transfer specimen to a plastic transport tube before freezing. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
    Reference notes
    • Negative: <4.4 μg Eq/mL • Equivocal: 4.4−10.7 μg Eq/mL • Positive: >10.7 μg Eq/mL
    Labcorp catalog page

Panels that include this biomarker

  • Immune Complexes Profile 054494

    2 analytes · Serum · Fasting not stated · Turnaround 4 - 9 days

    Method and collection
    Method
    C1q: enzyme immunoassay (EIA); C3d assay: enzyme immunoassay (EIA)
    Collection
    Transfer specimen to two plastic transport tubes before freezing. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
    Reference notes
    See individual tests.
    Labcorp catalog page

Quest Diagnostics 1 test

Single-analyte tests

  • Immune Complex Detection by C1q Binding 36735

    Serum · Fasting not stated · Turnaround Set up: Tues, Thurs; Report available: 6 days

    Method and collection
    Method
    Enzyme Linked Immunosorbent Immunoassay (ELISA)
    Collection
    Freeze serum within one hour of time drawn. With multiple tests, submit a separate tube for each test. Do not thaw.
    Reference notes
    ≤25.1 mcg Eq/mL
    Quest Diagnostics catalog page

0 of 5 tests selected

Pick one more

Sources

Verify these ranges and sources

We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.

Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.