Biomarker Lens

Common biomarkers

  • Hemoglobin
  • Glucose
  • ALT
  • Apolipoprotein B
  • C-Reactive Protein, Cardiac
  • Ferritin
  • Alb/Creat Ratio, Urine
  • Alkaline Phosphatase
  • FSH
  • T4,Free(Direct)

Biomarkers · Chemical

JAK2 V617F Mutation Quant Rslt

LOINC codes
43399-5
Tests that measure JAK2 V617F Mutation Quant Rslt
Labcorp 4, Quest Diagnostics 2

Ranges

Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ

Quest Diagnostics, Myeloproliferative Neoplasms (MPN) Core Diagnostic Panel 13010

PopulationInterval
JAK2 V617F MutationNot detected
JAK2 Exon 12 MutationNot detected
CALR Exon 9 MutationNot detected
MPL Exon 10 MutationNot detected

Quest Diagnostics test catalog, 13010

Tests

Check the catalog code, specimen, method and preparation for every test that measures JAK2 V617F Mutation Quant Rslt. Select up to five tests to compare them side by side.

Labcorp 4 tests

Single-analyte tests

  • JAK2 V617F Mutation Analysis, Qualitative 489200

    Blood · Fasting not stated · Turnaround 5 - 7 days

    Method and collection
    Method
    Allele-specific polymerase chain reaction (PCR); capillary electrophoresis
    Labcorp catalog page
  • JAK2 V617F Mutation Analysis, Quantitative 481020

    Blood · Fasting not stated · Turnaround 5 - 7 days

    Method and collection
    Method
    Total genomic DNA was extracted and subjected to TaqMan® real-time PCR amplification/detection. Two amplification products per sample were monitored by real-time PCR using primers/probes specific to JAK2 wild type (WT) and JAK2 mutant V617F. The ABI7900 Absolute Quantitation software will compare the patient specimen values to the standard curves and generate percent values for wild type and mutant type. The numerical values of sample Mutant Quantity/(Sample Mutant Quantity + Sample Wild Type Quantity) X100 is reported as a percentage.
    Collection
    Submit at room temperature. Specimen should arrive at the testing laboratory within 48 hours of collection. Indicate the date and time of collection on the test request form.
    Labcorp catalog page

Panels that include this biomarker

  • JAK2V617F + CALR + MPL NGS Panel 489615

    3 analytes · Blood · Fasting not stated · Turnaround 7 days

    Method and collection
    Method
    Amplicon-based Next Generation Sequencing
    Collection
    Submit at room temperature. Specimens should arrive in the laboratory within 48 hours of collection. Indicate date and time of collection on test request form.
    Labcorp catalog page
  • JAK2V617F Mutation Analysis, Quantitative With Reflex to CALR Mutation Analysis, JAK2 Exon 12-15 Mutation Analysis and MPL Mutation Analysis by NGS 489555

    3 analytes · Blood · Fasting not stated · Turnaround 7 days

    Method and collection
    Method
    Amplicon-based Next Generation Sequencing
    Collection
    Submit at room temperature. Specimens should arrive in the laboratory within 48 hours of collection. Indicate date and time of collection on test request form.
    Labcorp catalog page

Quest Diagnostics 2 tests

Single-analyte tests

  • JAK2 V617F Mutation Analysis 92473

    Blood · Fasting not stated · Turnaround Set up: Daily

    Method and collection
    Method
    Next-Generation Sequencing
    Reference notes
    See Laboratory Report
    Quest Diagnostics catalog page

Panels that include this biomarker

  • Myeloproliferative Neoplasms (MPN) Core Diagnostic Panel 13010

    2 analytes · Blood · Fasting not stated · Turnaround Set up: Daily

    Method and collection
    Method
    Next Generation Sequencing
    Collection
    Cell pellets: Send fixed samples within 7 days of fixation date in a plastic leak-proof container. Indicate type of fixative used along with patient name, specimen source, date collected, and date harvested/fixed. Cell pellets submitted in Carnoy's or other alcohol-based fixatives are acceptable. Extracted DNA: In addition, only accept extracted DNA when extraction or isolation is performed in an appropriately qualified laboratory such as a CLIA-certified laboratory or a laboratory meeting equivalent requirements as determined by the CAP and/or CMS.
    Quest Diagnostics catalog page

0 of 5 tests selected

Pick one more

Sources

Verify these ranges and sources

We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.

Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.