Biomarkers · Chemical
Mycoplasma hominis NAA
- LOINC codes
- 68546-1
- Tests that measure Mycoplasma hominis NAA
- Labcorp 4, Quest Diagnostics 1
Tests
Check the catalog code, specimen, method and preparation for every test that measures Mycoplasma hominis NAA. Select up to five tests to compare them side by side.
Labcorp 4 tests
Panels that include this biomarker
Genital Mycoplasma Profile, NAA, Swab 180089
3 analytes · Swab · Fasting not stated · Turnaround 3 - 4 days
Labcorp catalog pageMethod and collection
- Method
- Nucleic acid amplification (NAA)
- Collection
- Vaginal swab: Collect vaginal fluid sample using the Gen-Probe® Aptima® swab by contacting the swab to the lower third of the vaginal wall and rotating the swab for 10 to 30 seconds to absorb fluid. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Endocervical swab: Remove excess mucus from the cervical os and surrounding mucosa using the cleaning swab (white-shaft swab in the package with red printing). Discard this swab. Insert the specimen collection swab (blue-shaft swab in the package with green printing) into the endocervical canal. Gently rotate the swab clockwise for 10 to 30 seconds in the endocervical canal to ensure adequate sampling. Withdraw the swab carefully; avoid contact with the vaginal mucosa. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of the contents. Recap the swab specimen transport tube tightly. Male urethral swab: The patient should not have urinated for at least one hour prior to specimen collection. Insert the specimen collection swab (blue-shaft swab in the package with the green printing) 2 to 4 cm into the urethra. Gently rotate the swab clockwise for two to three seconds in the urethra to ensure adequate sampling. Withdraw the swab carefully. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the specimen transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of contents. Recap the swab specimen transport tube tightly.
Genital Mycoplasma Profile, NAA, Urine 180040
3 analytes · Urine · Fasting not stated · Turnaround 3 - 4 days
Labcorp catalog pageMethod and collection
- Method
- Nucleic acid amplification (NAA)
- Preparation
- The patient should not have urinated for at least one hour prior to specimen collection.
- Collection
- Urine specimen: The patient should not have urinated for at least one hour prior to specimen collection. Direct patient to provide a first-catch urine (approximately 20-30 mL of the initial urine stream) into a urine collection cup free of any preservatives. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity; lesser volumes may not adequately rinse organisms into the specimen. Female patients should not cleanse the labial area prior to providing the specimen. Add urine to the Aptima® Combo 2 urine collection device. The final volume must be between the two black lines on the device (about 2 mL).
Chlamydia/Gonococcus /Genital Mycoplasma Profile, NAA, Swab 180093
5 analytes · Swab · Fasting not stated · Turnaround 3 - 4 days
Labcorp catalog pageMethod and collection
- Method
- Nucleic acid amplification (NAA)
- Collection
- Vaginal swab: Collect vaginal fluid sample using the Aptima® swab by contacting the swab to the lower third of the vaginal wall and rotating the swab for 10 to 30 seconds to absorb fluid. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Endocervical swab: Remove excess mucus from the cervical os and surrounding mucosa using the cleaning swab (white-shaft swab in the package with red printing). Discard this swab. Insert the specimen collection swab (blue-shaft swab in the package with green printing) into the endocervical canal. Gently rotate the swab clockwise for 10 to 30 seconds in the endocervical canal to ensure adequate sampling. Withdraw the swab carefully; avoid contact with the vaginal mucosa. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of the contents. Recap the swab specimen transport tube tightly. Male urethral swab: The patient should not have urinated for at least one hour prior to specimen collection. Insert the specimen collection swab (blue-shaft swab in the package with the green printing) 2 to 4 cm into the urethra. Gently rotate the swab clockwise for two to three seconds in the urethra to ensure adequate sampling. Withdraw the swab carefully. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the specimen transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of contents. Recap the swab specimen transport tube tightly.
Chlamydia/Gonococcus /Genital Mycoplasma Profile, NAA, Urine 180051
5 analytes · Urine · Fasting not stated · Turnaround 3 - 4 days
Labcorp catalog pageMethod and collection
- Method
- Nucleic acid amplification (NAA)
- Preparation
- The patient should not have urinated for at least one hour prior to specimen collection.
- Collection
- Urine specimen: The patient should not have urinated for at least one hour prior to specimen collection. Direct patient to provide a first-catch urine (approximately 20 mL to 30 mL of the initial urine stream) into a urine collection container free of any preservatives. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity; lesser volumes may not adequately rinse organisms into the specimen. Female patients should not cleanse the labial area prior to providing the specimen. Add urine to the Aptima® Combo 2 urine collection device. The final volume must be between the two black lines on the device (about 2 mL).
Quest Diagnostics 1 test
Single-analyte tests
SureSwab®, Mycoplasma hominis, Real-Time PCR 91474
Urine · Fasting not stated · Turnaround Set up: Mon-Sat
Quest Diagnostics catalog pageMethod and collection
- Method
- Real-Time Polymerase Chain Reaction
- Preparation
- Male urine: Patient should not have urinated within one hour prior to collection.
- Collection
- Vaginal swabs: Follow instructions in the APTIMA® Vaginal Swab Collection Kit or Multitest Collection Kit (orange label). Male urethral swabs: Follow instructions in the APTIMA® Unisex Swab Specimen Collection Kit (white label). Swab specimen collection kit (orange or white label). Excess mucus should be removed prior to sampling. Male urine: Direct patient to provide a first-catch urine (a maximum of 20-30 mL of the initial urine stream) into a urine collection cup free of any preservatives. 2 mL of urine specimen must be transferred into the APTIMA® urine specimen transport within 24 hours of collection and before being assayed. Use the tube provided in the urine specimen collection kit. The fluid (urine plus transport media) level in the urine transport tube must fall within the clear pane on the tube label.
- Reference notes
- Not detected
0 of 5 tests selected
Pick one moreSources
4 tests: codes, specimens, methods, preparation and reference intervals.
Quest Diagnostics test catalog
1 test: codes, specimens, methods, preparation and reference intervals.
LOINC 68546-1
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for Mycoplasma hominis NAA
Registered studies that measure Mycoplasma hominis NAA, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.