Biomarkers · Chemical
Neisseria gonorrhoeae TMA Alternate Target Urogenital
- Also listed as
- na, plasma sodium, <em>Neisseria gonorrhoeae</em>, TMA (Alternate Target), Urogenital, serum sodium, Neisseria gonorrhoeae, TMA (Alternate Target), Urogenital
- LOINC codes
- 24111-7
- Tests that measure Neisseria gonorrhoeae TMA Alternate Target Urogenital
- Quest Diagnostics 1
Tests
Check the catalog code, specimen, method and preparation for every test that measures Neisseria gonorrhoeae TMA Alternate Target Urogenital. Select up to five tests to compare them side by side.
Quest Diagnostics 1 test
Single-analyte tests
Neisseria gonorrhoeae, TMA (Alternate Target), Urogenital 15033
Urine · Fasting not stated · Turnaround Set up: Tues
Quest Diagnostics catalog pageMethod and collection
- Method
- Dual Kinetic Assay (DKA) • Target Capture • Transcription-Mediated Amplification (TMA)
- Collection
- Swabs: Swab must be submitted in APTIMA® Multitest collection Kit (orange label), or Unisex Swab Specimen Collection Kit (white label). Follow instructions in the APTIMA® Swab Specimen Collection Kits for Vaginal, Endocervical and Urethral Swab Specimens package insert. In females, to ensure collection of an adequate specimen, columnar epithelial cells lining the endocervix should be obtained. To that effect, excess mucus should be removed prior to sampling by using the white shaft cleaning swab which is discarded after use. Collection Container: APTIMA® Multitest Collection Tube (orange label), or Unisex Swab Specimen Collection Tube (white label). Urine: Urine must be submitted in APTIMA® Urine Specimen Collection Tube within 24 hours of collection. The patient should not have urinated for at least one hour prior to specimen collection. Direct patient to provide a first-catch urine (approximately 20-30 mL of the initial urine stream) into a urine collection cup free of any preservatives. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity. Female patients should not cleanse the labial area prior to providing the specimen. Thus, a urine sample collected from a female for Chlamydia/GC TMA cannot be collected at the same voiding event as that urine which would be intended for bacterial culture. Remove the cap of the APTIMA® Urine Specimen Collection Tube and transfer 2 mL of urine into the urine specimen transport tube using the disposable pipette provided. The correct volume of urine has been added when the fluid level is between the black lines within the clear pane on the urine specimen transport tube label. Collection Container: APTIMA® Urine Specimen Collection Tube (white label). ThinPrep® PreservCyt®: Transfer 1 mL of ThinPrep® PreservCyt® solution into APTIMA® Specimen Transfer Tube (green label) or APTIMA® Multitest Collection Tube (orange label).
- Reference notes
- Not detected
0 of 5 tests selected
Pick one moreSources
Quest Diagnostics test catalog
1 test: codes, specimens, methods, preparation and reference intervals.
LOINC 24111-7
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for Neisseria gonorrhoeae TMA Alternate Target Urogenital
Registered studies that measure Neisseria gonorrhoeae TMA Alternate Target Urogenital, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.