Biomarkers · Chemical
Normetanephrine
- Also listed as
- Normetanephrine, Pl
- Primary unit
- pg/mL
- LOINC codes
- 2669-0
- Tests that measure Normetanephrine
- Labcorp 1, Quest Diagnostics 1
Ranges
Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ
Quest Diagnostics, Metanephrines, Fractionated, Free, LC/MS/MS, Plasma 19548
| Population | Interval |
|---|---|
| Metanephrine, Free | ≤57 pg/mL |
| Normetanephrine, Free | ≤148 pg/mL |
| Total, Free (MN + NMN) | ≤205 pg/mL |
Tests
Check the catalog code, specimen, method and preparation for every test that measures Normetanephrine. Select up to five tests to compare them side by side.
Labcorp 1 test
Panels that include this biomarker
Metanephrines, Fractionated, Plasma Free 121806
2 analytes · Plasma · Fasting not stated · Turnaround 3 - 6 days
Labcorp catalog pageMethod and collection
- Method
- Liquid chromatography/tandem mass spectrometry (LC/MS-MS)
- Preparation
- Patient should be fasting overnight (water and non-caffeinated soft drinks are permissible). Patient should avoid alcohol, coffee, tea, tobacco and strenuous exercise prior to collection. See Limitations section for more information about other potential causes of elevated metanephrines.
- Collection
- Draw blood in chilled lavender-top (EDTA) tube. Invert to mix with preservatives. Centrifuge and transfer the plasma to a labeled plastic transport tube. Refrigerate or freeze separated plasma immediately. Important: The patient should be in a fully recumbent position (lying down) for at least 20 minutes before and during sample collection.
- Reference notes
- Metanephrine, Pl Age | Male | Female All ages | 0.0–88.0 | 0.0–88.0 Normetanephrine, Pl Age | Male | Female 0 to 4 y | Not established | Not established 5 to 11 y | 0.0–165.9 | 0.0–148.0 12 to 19 y | 0.0–150.8 | 0.0–150.8 20 to 40 y | 0.0–210.1 | 0.0–210.1 41 to 50 y | 0.0–218.9 | 0.0–218.9 51 to 60 y | 0.0–244.0 | 0–244.0 61 to 80 y | 0.0–285.2 | 0.0–285.2 >80 y | 0.0–297.2 | 0.0–297.2 Adult reference intervals applied to free metanephrines were originally developed by Eisenhofer and coworkers10 and further validated in subsequent studies.11,12 Recognizing the potential deadly consequences of a missed diagnosis, cutoffs of reference were established to ensure optimum diagnostic sensitivity, with specificity a secondary consideration. Subjects fasted and abstained from caffeinated and decaffeinated beverages overnight. Plasma samples collected after at least 20 minutes of supine rest. For plasma metabolites, optimal performance was obtained using age-specific reference intervals for normetanephrine,10,11 and for metanephrine single cut-offs for males and females that were slightly above 99.5 percentiles contributed to optimized performance.11,12
Quest Diagnostics 1 test
Panels that include this biomarker
Metanephrines, Fractionated, Free, LC/MS/MS, Plasma 19548
3 analytes · Plasma · Fasting not stated · Turnaround Set up: Mon-Sat (p.m.); Report available: 5-6 days
Quest Diagnostics catalog pageMethod and collection
- Method
- Chromatography/Mass Spectrometry
- Preparation
- Patients should be relaxed in either a supine or upright position before blood is drawn. Patient should avoid alcohol, coffee, tea, tobacco and strenuous exercise prior to collection. Overnight fasting is preferred.
- Collection
- Draw specimen in a pre-chilled EDTA lavender-top Vacutainer™. The whole blood sample should be kept on wet ice until centrifuged (preferably at 4° C) to separate the plasma within 2 hours of venipuncture. After centrifugation, the plasma should be transferred to a transport tube and immediately refrigerated.
0 of 5 tests selected
Pick one moreSources
1 test: codes, specimens, methods, preparation and reference intervals.
Quest Diagnostics test catalog
1 test: codes, specimens, methods, preparation and reference intervals.
LOINC 2669-0
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for Normetanephrine
Registered studies that measure Normetanephrine, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.