Biomarkers · Chemical
PAPP-A (Pregnancy-associated Plasma Protein-A) from Maternal Serum
- LOINC codes
- 11778-8, 11878-6, 11884-4, 1834-1, 21112-8, 21198-7, 21264-7, 21484-1, 2250-9, 23811-3, 23841-0, 23883-2, 3142-7, 32123-2, 33882-2, 36904-1, 43994-3, 43995-0, 44877-9, 44951-2, 46608-6, 47224-1, 48407-1, 48803-1, 49053-2, 49090-4, 49586-1, 55752-0, 64234-8, 81230-5
- Tests that measure PAPP-A (Pregnancy-associated Plasma Protein-A) from Maternal Serum
- Quest Diagnostics 1
Tests
Check the catalog code, specimen, method and preparation for every test that measures PAPP-A (Pregnancy-associated Plasma Protein-A) from Maternal Serum. Select up to five tests to compare them side by side.
Quest Diagnostics 1 test
Panels that include this biomarker
Serum Integrated Screen, Part 2 16167
6 analytes · Serum · Fasting not stated · Turnaround Set up: Mon-Fri (a.m.); Report available: Tues-Fri, Mon p.m.
Quest Diagnostics catalog pageMethod and collection
- Method
- Chemiluminescence (CL) • Immunoassay (IA)
- Collection
- Collect between 14.0 weeks to 22 6/7 weeks. Maternal date of birth (mm/dd/yy), estimated date of delivery by US/LMP/PE, weight, race, insulin-dependent diabetes status, repeat sample (Y/N), number of fetuses, and neural tube defect history must be provided for interpretation of results. Must complete patient demographic information using the Maternal Serum Screen Requisition.
0 of 5 tests selected
Pick one moreSources
Quest Diagnostics test catalog
1 test: codes, specimens, methods, preparation and reference intervals.
LOINC 11778-8, 11878-6, 11884-4, 1834-1, 21112-8, 21198-7, 21264-7, 21484-1, 2250-9, 23811-3, 23841-0, 23883-2, 3142-7, 32123-2, 33882-2, 36904-1, 43994-3, 43995-0, 44877-9, 44951-2, 46608-6, 47224-1, 48407-1, 48803-1, 49053-2, 49090-4, 49586-1, 55752-0, 64234-8, 81230-5
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for PAPP-A (Pregnancy-associated Plasma Protein-A) from Maternal Serum
Registered studies that measure PAPP-A (Pregnancy-associated Plasma Protein-A) from Maternal Serum, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.