Biomarkers · Chemical
Plasminogen Act Inhibitor-1
- Primary unit
- IU/mL
- LOINC codes
- 5975-8
- Tests that measure Plasminogen Act Inhibitor-1
- Labcorp 4
Tests
Check the catalog code, specimen, method and preparation for every test that measures Plasminogen Act Inhibitor-1. Select up to five tests to compare them side by side.
Labcorp 4 tests
Single-analyte tests
Plasminogen Activator Inhibitor 1 (PAI-1) Activity 146787
Plasma · Fasting not stated · Turnaround 3 - 5 days
Labcorp catalog pageMethod and collection
- Method
- Enzyme-linked immunosorbent assay (ELISA)
- Collection
- Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Panels that include this biomarker
Thrombotic Risk, Congenital (Extended) 117185
6 analytes · Serum · Fasting not stated · Turnaround 3 - 7 days
Labcorp catalog pageMethod and collection
- Method
- See individual tests.
- Preparation
- Do not draw from an arm with a heparin lock or heparinized catheter.
- Collection
- Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anti-coagulant with the blood. A discard tube is not required prior to collection of coagulation samples except when using a winged blood collection device (i.e., "butterfly"), in which case a discard tube should be used.4,5 When non-citrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap and recentifuge for 10 minutes. Use a second plastic pipette to remove plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. It is important to centrifuge blood samples for plasma collection immediately after collection to separate the plasma from the blood cells. If immediate centrifugation is not possible, collected blood specimens should be kept on ice and centrifuged within an hour. Other plasma : It is important to centrifuge blood samples for plasma collection immediately after collection to separate the plasma from the blood cells. If immediate centrifugation is not possible, collected blood specimens should be kept on ice and centrifuged within an hour. Serum: Sample should be centrifuged as soon as possible after collection to avoid false elevation of homocysteine and transported in a completely separated gel barrier-tube (SST) or transfer tube. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Fibrinolysis Profile 117310
7 analytes · Plasma · Fasting not stated · Turnaround 5 - 8 days
Labcorp catalog pageMethod and collection
- Method
- See individual tests.
- Collection
- Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.27 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.28,29 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples.30,31 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Double centrifugation is required for this test to ensure the removal of platelets that contain fibrinolysis factors.32,33 Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Bleeding With Normal aPTT/PT 117700
9 analytes · Plasma · Fasting not stated · Turnaround 4 - 5 days
Labcorp catalog pageMethod and collection
- Method
- See individual tests.
- Preparation
- Do not draw from an arm with a heparin lock or heparinized catheter.
- Collection
- Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tubes. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and (using a plastic transfer pipette) carefully remove two-thirds of the plasma without disturbing the cells. Deliver to a plastic transfer tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a LabCorp PP transpak frozen purple tube with screw cap (LabCorp No. 49482). The specimen should be frozen immediately and maintained frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
0 of 5 tests selected
Pick one moreSources
Check the guidelines, studies and lab catalogs behind every range and link on this page. Open a source to see each claim it backs.
Lab catalogs
Labcorp test menu
Labcorp
Test catalog: 4 tests, with codes, specimens, methods and reference intervals
Codes and registries
LOINC 5975-8
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for Plasminogen Act Inhibitor-1
Registered studies that measure Plasminogen Act Inhibitor-1, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.