Biomarkers · Chemical
Protein S Antigen Free
- Also listed as
- Protein S Antigen, Free, Protein S Antigen
- LOINC codes
- 27821-8, 27822-6, 27823-4, 13965-9, 16135-6, 16136-4, 21108-6, 21667-1, 21668-9, 24475-6, 24476-4, 27811-9, 27819-2, 3181-5, 3182-3, 34571-0, 5076-5, 56850-1, 6303-2, 75514-0, 85358-0, 85359-8, 77202-0, 13590-5, 3209-4
- Tests that measure Protein S Antigen Free
- Quest Diagnostics 6
Tests
Check the catalog code, specimen, method and preparation for every test that measures Protein S Antigen Free. Select up to five tests to compare them side by side.
Quest Diagnostics 6 tests
Panels that include this biomarker
Protein S Activity, Antigen, Total and Free 93355
2 analytes · Plasma · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Clotting Assay • Immunoturbidimetric Assay
- Collection
- Please submit a separate, frozen vial for each special coagulation assay ordered. Draw blood in a light blue-top tube containing 3.2% sodium citrate, mix gently by inverting 3-4 times. Centrifuge 15 minutes at 1500 g within one hour of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial(s). Freeze immediately and transport on dry ice.
- Reference notes
- See individual tests
Thrombophilia Screen II, Inherited 11327
4 analytes · Plasma · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Polymerase Chain Reaction & Detection • Chromogenic Substrate • Clotting Assay • Immunoturbidimetric Reflex: Fluorescent Microspheres • Oligonucleotide Ligation Assay • Polymerase Chain Reaction (PCR)
- Collection
- This panel requires platelet-poor plasma and whole blood. Please submit a separate, frozen vial for each special coagulation assay ordered. Draw blood in a light blue-top tube containing 3.2% sodium citrate, mix gently by inverting 3-4 times. Centrifuge 15 minutes at 1500 g within one hour of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial(s). Freeze immediately and transport on dry ice. Whole blood: Preferred shipping temperature is frozen, but room temperature shipping is acceptable.
- Reference notes
- See Laboratory Report
Venous Thrombosis Hypercoagulability Panel with Reflex 11475
10 analytes · Plasma · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Chromogenic Clotting Assay • Enzyme Immunoassay (EIA) • Immunoturbidimetric Immunoassay • Polymerase Chain Reaction and Detection
- Collection
- Whole blood sample is for the Factor V Mutation Analysis and Prothrombin (Factor II) Mutation Analysis. Platelet-poor plasma is for remaining tests. Platelet-poor plasma: Centrifuge light blue-top tube 15 minutes at approximately 1500 x g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into six plastic vials. Plasma must be free of platelets (<10,000/mcL). Freeze immediately and ship on dry ice. Note: Storage of whole blood at refrigerated temperatures prior to processing may lead to cryoprecipitate formation and falsely low Factor VIII and von Willebrand Factor studies.
- Reference notes
- See Laboratory Report
Recurrent Miscarriage/Coagulation Panel with Reflex (without Consultation) 11469
11 analytes · Plasma · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Chromogenic Clotting Assay • Enzyme Immunoassay (EIA) • Immunoturbidimetric Immunoassay • Polymerase Chain Reaction and Detection
- Collection
- Whole blood sample is for the Factor V Mutation Analysis and Prothrombin (Factor II) Mutation Analysis. Platelet-poor plasma is for remaining tests. Platelet-poor plasma: Centrifuge light blue-top tube 15 minutes at approximately 1500 x g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into four plastic vials. Plasma must be free of platelets (<10,000/mcL). Freeze immediately and ship on dry ice.
- Reference notes
- See Laboratory Report
Venous Thrombosis Hypercoagulability Panel with Reflex and Consultation 19656
12 analytes · Serum · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- See individual tests
- Collection
- Whole blood sample is for the Factor V Mutation Analysis and Prothrombin (Factor II) Mutation Analysis. Serum sample is for the Homocysteine. Red-top tubes: Place the specimen in a refrigerator or ice bath for 30 minutes after collection. Centrifuge the specimen as soon as possible after complete clot formation has taken place. Transfer the serum to a plastic screw-capped vial. Barrier gel separator tubes: Place the specimen in a refrigerator for 30 minutes after collection. Centrifuge the specimen as soon as possible after complete clot formation has taken place. Do not place barrier tubes in an ice bath as freezing may prevent the barrier gel from adequately separating serum from cells. Platelet-poor plasma is for the remaining tests. Platelet-poor plasma: Centrifuge light blue-top tube 15 minutes at approximately 1500 g within 60 minutes of collection using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into six new plastic vials. Plasma must be free of platelets (<10,000/mcL). Freeze immediately and ship on dry ice. Note: Storage of whole blood at refrigerated temperatures prior to processing may lead to cryoprecipitate formation and falsely low Factor VIII and von Willebrand Factor studies.
- Reference notes
- See Laboratory Report
0 of 5 tests selected
Pick one moreSources
Quest Diagnostics test catalog
6 tests: codes, specimens, methods, preparation and reference intervals.
LOINC 27821-8, 27822-6, 27823-4, 13965-9, 16135-6, 16136-4, 21108-6, 21667-1, 21668-9, 24475-6, 24476-4, 27811-9, 27819-2, 3181-5, 3182-3, 34571-0, 5076-5, 56850-1, 6303-2, 75514-0, 85358-0, 85359-8, 77202-0, 13590-5, 3209-4
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for Protein S Antigen Free
Registered studies that measure Protein S Antigen Free, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.