Biomarkers · Chemical
PS/PT IgG
- Primary unit
- Units
- LOINC codes
- 14245-5
- Tests that measure PS/PT IgG
- Labcorp 4
Tests
Check the catalog code, specimen, method and preparation for every test that measures PS/PT IgG. Select up to five tests to compare them side by side.
Labcorp 4 tests
Panels that include this biomarker
Phosphatidylserine/Prothrombin Antibody (PS/PT), IgG and IgM 117985
2 analytes · Serum · Fasting not stated · Turnaround 3 - 5 days
Labcorp catalog pageMethod and collection
- Method
- Enzyme-linked immunosorbent assay (ELISA)
- Collection
- Separate serum from cells by centrifugation after clot formation.
- Reference notes
- • IgG = 0–20 Units • IgM = 0–50 Units Reference ranges developed by Labcorp internal study.
Thrombotic Risk, Acquired 117145
11 analytes · Serum · Fasting not stated · Turnaround 3 - 7 days
Labcorp catalog pageMethod and collection
- Method
- See individual tests.
- Preparation
- Do not draw from an arm with a heparin lock or heparinized catheter.
- Collection
- Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anti-coagulant with the blood. A discard tube is not required prior to collection of coagulation samples except when using a winged blood collection device (i.e., "butterfly"), in which case a discard tube should be used.4,5 When non-citrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap and recentifuge for 10 minutes. Use a second plastic pipette to remove plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. It is important to centrifuge blood samples for plasma collection immediately after collection to separate the plasma from the blood cells. If immediate centrifugation is not possible, collected blood specimens should be kept on ice and centrifuged within an hour. Serum: If a red-top tube is used, transfer separate serum to a plastic transport tube. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Antiphospholipid Syndrome (APS) Assessment 164535
14 analytes · Serum · Fasting not stated · Turnaround 4 - 6 days
Labcorp catalog pageMethod and collection
- Method
- Clot-based assays for lupus anticoagulants and enzyme-linked immunoassays (ELISAs) for antiphospholipid antibodies
- Preparation
- Do not draw from an arm with a heparin lock or heparinized catheter.
- Collection
- Plasma: Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.26 Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio.27,28 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anti-coagulant with the blood. A discard tube is not required prior to collection of coagulation samples except when using a winged blood collection device (i.e., "butterfly"), in which case a discard tube should be used.29,30 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap and recentifuge for 10 minutes. Use a second plastic pipette to remove plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . It is important to centrifuge blood samples for plasma collection immediately after collection to separate the plasma from the blood cells. If immediate centrifugation is not possible, collected blood specimens should be kept on ice and centrifuged within an hour. Serum: If a red-top tube is used, transfer separate serum to a plastic transport tube. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Thrombotic Risk Assessment 117155
14 analytes · Serum · Fasting not stated · Turnaround 3 - 7 days
Labcorp catalog pageMethod and collection
- Method
- See individual tests.
- Preparation
- Do not draw from an arm with a heparin lock or heparinized catheter.
- Collection
- Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anti-coagulant with the blood. A discard tube is not required prior to collection of coagulation samples except when using a winged blood collection device (i.e., "butterfly"), in which case a discard tube should be used.4,5 When non-citrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap and recentifuge for 10 minutes. Use a second plastic pipette to remove plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. It is important to centrifuge blood samples for plasma collection immediately after collection to separate the plasma from the blood cells. If immediate centrifugation is not possible, collected blood specimens should be kept on ice and centrifuged within an hour. Serum: If a red-top tube is used, transfer separate serum to a plastic transport tube. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
0 of 5 tests selected
Pick one moreSources
4 tests: codes, specimens, methods, preparation and reference intervals.
LOINC 14245-5
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for PS/PT IgG
Registered studies that measure PS/PT IgG, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.