Thyroglobulin Antibody

Primary unit
IU/mL
LOINC codes
8098-6
Tests that measure Thyroglobulin Antibody
Quest Diagnostics 6, Labcorp 5

Ranges

Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ

Quest Diagnostics, Thyroid Cancer (Thyroglobulin) Monitor 90814

PopulationInterval
Thyroglobulin Antibody≤2 IU/mL
ThyroglobulinAthyrotic: <0.1 ng/mL
Thyroglobulin, LC/MS/MSAthyrotic: <0.4 ng/mL

Quest Diagnostics test catalog, 90814

Tests

Check the catalog code, specimen, method and preparation for every test that measures Thyroglobulin Antibody. Select up to five tests to compare them side by side.

Quest Diagnostics 6 tests

Single-analyte tests

  • Thyroglobulin Antibodies 267

    Serum · Fasting not stated · Turnaround Set up: Mon-Fri (Day shift); Report available: 5 days

    Method and collection
    Method
    Immunoassay (IA)
    Collection
    Administration of STRENSIQ may interfere in certain assays and may falsely elevate values. For patients receiving STRENSIQ, consideration should be given to using alternate methods.
    Reference notes
    ≤2 IU/mL
    Quest Diagnostics catalog page
  • Thyroid Cancer (Thyroglobulin) Monitor 90814

    Serum · Fasting not stated · Turnaround Set up: Mon-Fri

    Method and collection
    Method
    Immunoassay (IA) • Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)
    Collection
    Administration of STRENSIQ may interfere in certain assays and may falsely elevate values. For patients receiving STRENSIQ, consideration should be given to using alternate methods.
    Quest Diagnostics catalog page

Panels that include this biomarker

  • Thyroid Peroxidase and Thyroglobulin Antibodies 7260

    2 analytes · Serum · Fasting not stated

    Method and collection
    Method
    Immunoassay (IA)
    Collection
    Administration of STRENSIQ may interfere in certain assays and may falsely elevate values. For patients receiving STRENSIQ, consideration should be given to using alternate methods.
    Reference notes
    Thyroid Peroxidase Ab | <9 IU/mL Thyroglobulin Ab | ≤2 IU/mL
    Quest Diagnostics catalog page
  • Chronic Urticaria Panel 1 16440

    4 analytes · Serum · Fasting not stated

    Method and collection
    Method
    See individual tests
    Preparation
    Patients taking calcineurin inhibitors should stop their medication for 72 hours prior to draw. Specimen collection after fluorescein dye angiography should be delayed for at least 3 days. For patients on hemodialysis, specimen collection should be delayed for 2 weeks after angiography. According to the assay manufacturer Siemens: samples containing fluorescein can produce falsely depressed values. Dietary supplements containing biotin may interfere in assays and may skew results to be either falsely high or falsely low. For patients receiving the recommended daily doses of biotin, draw samples at least 8 hours following the last biotin supplementation. For patients on mega-doses of biotin supplements, draw samples at least 72 hours following the last biotin supplementation.
    Reference notes
    See individual tests
    Quest Diagnostics catalog page
  • Thyroglobulin Panel with HAMA Treatment 19584

    4 analytes · Serum · Fasting not stated · Turnaround Set up: Tues-Sat

    Method and collection
    Method
    Immunoassay (IA)
    Collection
    Administration of STRENSIQ may interfere in certain assays and may falsely elevate values. For patients receiving STRENSIQ, consideration should be given to using alternate methods.
    Reference notes
    See Laboratory Report
    Quest Diagnostics catalog page
  • Chronic Urticaria Panel 2 (Comprehensive) 90123

    5 analytes · Serum · Fasting not stated

    Method and collection
    Method
    See individual tests
    Preparation
    Patients taking calcineurin inhibitors should stop their medication for 72 hours prior to draw. Specimen collection after fluorescein dye angiography should be delayed for at least 3 days. For patients on hemodialysis, specimen collection should be delayed for 2 weeks after angiography. According to the assay manufacturer Siemens: samples containing fluorescein can produce falsely depressed values.
    Collection
    Serum should be separated from the cells as soon as possible after visible clot formation (usually 15-30 minutes after collection).
    Reference notes
    See individual tests
    Quest Diagnostics catalog page

Labcorp 5 tests

Single-analyte tests

  • Thyroglobulin Antibody 006685

    Serum · Fasting not stated · Turnaround 1 - 3 days

    Method and collection
    Method
    Immunochemiluminometric assay (ICMA). This assay is performed using Beckman Coulter Methodology in multiple laboratories throughout Labcorp.
    Collection
    Separate serum from cells, and transfer specimen to a plastic transport tube.
    Labcorp catalog page
  • Thyroglobulin Antibody and Thyroglobulin, IMA or LC/MS-MS 042045

    Serum · Fasting not stated · Turnaround 1 - 5 days

    Method and collection
    Method
    TgAb: Beckman Coulter immunometric assay; Tg-IMA: Beckman Coulter immunometric assay; Tg: Liquid chromatography/tandem mass spectrometry (LC/MS-MS) lab-developed test. Both Tg assays are calibrated against CRM-57 international standard for Tg as recommended in recent guidance documents.1 LabCorp uses a dual Tg strategy in an effort to eliminate the potential effect of TgAb interference on Tg analysis. All specimens are initially assayed for TgAb by the highly sensitive Beckman Coulter IMA. Samples with TgAb below the detectable limit are assayed for Tg by a sensitive second-generation IMA (Beckman Coulter) with a relatively rapid turnaround time. Specimens with any measurable levels of TgAb are assayed by a sensitive LC/MS-MS method.
    Collection
    Separate serum from cells, and transfer specimen to a plastic transport tube.
    Labcorp catalog page
  • Thyroglobulin Antibody and Thyroglobulin, IMA or RIA 042060

    Serum · Fasting not stated · Turnaround 1 - 4 days

    Method and collection
    Method
    Immunometric assay (IMA and radioimmunoassay (RIA); Anti-Tg: Beckman Coulter immunometric assay; Tg IMA: Beckman Coulter immunometric assay; Tg RIA: Lab-developed radioimmunoassay LabCorp uses a dual Tg test strategy in an effort to minimize the potential effect of TgAb interference on Tg analysis. All specimens are initially assayed for TgAb by the highly sensitive Beckman Coulter IMA. Samples with TgAb below the detectable limit are assayed for Tg by a sensitive second-generation IMA (Beckman Coulter) with a relatively rapid turnaround time. Specimens with any measurable levels of TgAb are assayed by an RIA method performed at Endocrine Sciences, Calabasas Hills, Calif. This RIA is resistant to interference by TgAb but has a longer turnaround time of five to seven days.
    Collection
    Separate serum from cells, and transfer specimen to a plastic transport tube.
    Labcorp catalog page

Panels that include this biomarker

  • Thyroglobulin, Comprehensive (With Anti-Tg Screen and Reflex to RIA) (Endocrine Sciences) 500540

    2 analytes · Serum · Fasting not stated · Turnaround 4 - 10 days

    Method and collection
    Method
    Immunochemiluminometric (ICMA) or double antibody radioimmunoassay (RIA) when anti-Tg autoantibodies are present
    Collection
    Transfer specimen to a plastic transport tube before freezing. Serum must be separated from cells within one hour of venipuncture. Submit serum in a plastic transport tube.
    Labcorp catalog page
  • Thyroid Antibodies 006684

    2 analytes · Serum · Fasting not stated · Turnaround 1 - 3 days

    Method and collection
    Method
    See individual test descriptions.
    Labcorp catalog page

0 of 5 tests selected

Pick one more

Sources

Check the guidelines, studies and lab catalogs behind every range and link on this page. Open a source to see each claim it backs.

Lab catalogs

Codes and registries

Verify these ranges and sources

We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.

Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.