Biomarker Lens

Common biomarkers

  • Hemoglobin
  • Glucose
  • ALT
  • Apolipoprotein B
  • C-Reactive Protein, Cardiac
  • Ferritin
  • Alb/Creat Ratio, Urine
  • Alkaline Phosphatase
  • FSH
  • T4,Free(Direct)

Biomarkers · Chemical

Vancomycin Peak

Also listed as
serum potassium, k, plasma potassium, Vancomycin, Peak, Vancomycin Peak, Serum
Primary unit
ug/mL
LOINC codes
4090-7
Tests that measure Vancomycin Peak
Labcorp 1, Quest Diagnostics 1

Tests

Check the catalog code, specimen, method and preparation for every test that measures Vancomycin Peak. Select up to five tests to compare them side by side.

Labcorp 1 test

Single-analyte tests

  • Vancomycin, Serum, Peak 070327

    Serum · Fasting not stated · Turnaround Within 1 day

    Method and collection
    Method
    Immunoassay
    Collection
    Transfer separated serum or plasma to a plastic transport tube. Both peak and trough concentrations should be monitored. The trough sample is drawn immediately prior to the next dose.
    Reference notes
    • Therapeutic: 25.0−40.0 μg/mL • Detection limit: 2.0 μg/mL; <2.0 μg/mL indicates none detected Note: Peak levels drawn at 30 minutes are more variable and very dependent on consistent timing of collections. Differences of as little as 15 minutes in sampling time can result in a 10−15 μg/mL difference in measured vancomycin concentrations. It is important that consistency be maintained in the dosage interval and infusion period throughout the course of therapy for comparison of vancomycin concentrations to be valid. Peak levels collected at two hours are less variable.
    Labcorp catalog page

Quest Diagnostics 1 test

Single-analyte tests

  • Vancomycin, Peak 8578

    Serum · Fasting not stated · Turnaround Set up: Daily (All shifts); Report available: 1 day

    Method and collection
    Method
    Immunoassay (IA)
    Preparation
    Collect peak sample 1 hour after completion of the drug infusion
    Reference notes
    20.0-40.0 mg/L
    Quest Diagnostics catalog page

0 of 5 tests selected

Pick one more

Sources

Verify these ranges and sources

We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.

Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.