Biomarkers · Chemical
Arsenic (Total),Ur, Urine
- Primary unit
- ug/L
- LOINC codes
- 5586-3
- Tests that measure Arsenic (Total),Ur, Urine
- Labcorp 4, Quest Diagnostics 3
Tests
Check the catalog code, specimen, method and preparation for every test that measures Arsenic (Total),Ur, Urine. Select up to five tests to compare them side by side.
Labcorp 4 tests
Panels that include this biomarker
Arsenic Exposure Profile, Urine 007045
3 analytes · Urine · Fasting not stated · Turnaround 3 - 6 days
Labcorp catalog pageMethod and collection
- Method
- Inductively-coupled plasma-mass spectrometry (ICP-MS)
- Preparation
- Patient must avoid all seafood for 72 hours prior to collection. Seafood consumption two to three days prior to specimen collection can markedly elevate levels of total arsenic in urine. This dietary form of arsenic is nontoxic and is comprised primarily of arsenobetaine and arsenocholine. Inorganic arsenic is used for industrial exposure monitoring.
- Collection
- Sampling time is the end of the work week for industrial exposure monitoring. Metals with timing "end of work week" (meaning four or five consecutive working days with exposure) are eliminated with half-lives longer than five hours. Such metals accumulate in the body during the work week; therefore, their timing is critical in relation to previous exposures. Optional protocol : Instruct the patient to void at 8 AM and discard the specimen. Then collect all urine including the final specimen voided at the end of the 24-hour collection period (ie, 8 AM the next morning). Avoid contact with metal during collection. Screw the lid on securely.
- Reference notes
- • Environmental exposure: Total arsenic: 0−9 μg/L, 0−50 μg/24 hours; inorganic arsenic: <20 μg/L • Occupational exposure: BEI®, inorganic arsenic plus methylated metabolites (sampling time is end of work week): 35 μg/L creatinine1
Heavy Metals Profile I, Urine 007046
9 analytes · Urine · Fasting not stated · Turnaround 3 - 6 days
Labcorp catalog pageMethod and collection
- Method
- Inductively coupled plasma-mass spectrometry (ICP-MS)
- Preparation
- Patient should avoid seafood and red wine 72 hours prior to collection.
- Collection
- Sampling time is not critical for industrial monitoring. Optional protocol : Instruct the patient to void at 8 AM and discard the specimen. Then collect all urine including the final specimen voided at the end of the 24-hour collection period (ie, 8 AM the next morning). Avoid contact with metal during collection. Screw the lid on securely. See individual tests for collection times for industrial monitoring.
Heavy Metals Profile II, Urine 250281
12 analytes · Urine · Fasting not stated · Turnaround 3 - 6 days
Labcorp catalog pageMethod and collection
- Method
- Inductively-coupled plasma/mass spectrometry (ICP/MS)
- Preparation
- Patient should avoid seafood and red wine 72 hours prior to collection.
- Collection
- Optional protocol : Instruct the patient to void at 8 AM and discard the specimen. Then collect all urine including the final specimen voided at the end of the 24-hour collection period (ie, 8 AM the next morning). Avoid contact with metal during collection. Screw the lid on securely. See individual tests for collection times for industrial monitoring.
- Reference notes
- See individual tests.
Common Alloy Elements Profile 007069
21 analytes · Urine · Fasting not stated · Turnaround 3 - 5 days
Labcorp catalog pageMethod and collection
- Method
- Inductively-coupled plasma-mass spectrometry (ICP/MS)
- Preparation
- Patient must avoid seafood and red wine 72 hours prior to collection.
- Collection
- Collect 24-hour urine without preservatives. Mix well.
Quest Diagnostics 3 tests
Panels that include this biomarker
Metals/Metalloids Panel 1, Urine 30323
4 analytes · Urine · Fasting not stated · Turnaround Set up: Mon-Sat
Quest Diagnostics catalog pageMethod and collection
- Method
- Colorimetry (C) • Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
- Preparation
- Avoid exposure to gadolinium-based contrast media for 48 hours prior to sample collection. Avoid seafood consumption for 48 hours prior to sample collection.
- Collection
- Unpreserved urine should be refrigerated immediately and analyzed within 1 week of collection. Acceptable preservatives include: Trace metal-free hydrochloric acid or nitric acid (0.1 mL of 12M acid/10 mL urine).
- Reference notes
- See Laboratory Report
Heavy Metals Panel 4, Urine (CSA) 34695
8 analytes · Urine · Fasting not stated · Turnaround Set up: Mon, Tues, Thurs; Report available: 7 days
Quest Diagnostics catalog pageMethod and collection
- Method
- Colorimetry (C) • Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
- Preparation
- Avoid exposure to gadolinium-based contrast media for 48 hours prior to sample collection. Avoid seafood consumption for 48 hours prior to sample collection.
- Collection
- Unpreserved urine should be refrigerated immediately and analyzed within 1 week of collection. Acceptable preservatives include: Trace metal-free hydrochloric acid or nitric acid (0.1 mL of 12M acid/10 mL urine).
- Reference notes
- See Laboratory Report
Heavy Metals Panel 5A, Urine (CSA) 35402
11 analytes · Urine · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Colorimetry (C) • Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
- Preparation
- Avoid exposure to gadolinium-based contrast media for 48 hours prior to sample collection. Avoid seafood consumption for 48 hours prior to sample collection.
- Collection
- Unpreserved urine should be refrigerated immediately and analyzed within 1 week of collection. Acceptable preservatives include: Trace metal-free hydrochloric acid or nitric acid (0.1 mL of 12M acid/10 mL urine).
- Reference notes
- See Laboratory Report
0 of 5 tests selected
Pick one moreSources
Check the guidelines, studies and lab catalogs behind every range and link on this page. Open a source to see each claim it backs.
Lab catalogs
Labcorp test menu
Labcorp
Test catalog: 4 tests, with codes, specimens, methods and reference intervals
Quest Diagnostics test menu
Quest Diagnostics
Test catalog: 3 tests, with codes, specimens, methods and reference intervals
Codes and registries
LOINC 5586-3
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for Arsenic (Total),Ur, Urine
Registered studies that measure Arsenic (Total),Ur, Urine, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.