Biomarker Lens

Common biomarkers

  • Hemoglobin
  • Glucose
  • ALT
  • Apolipoprotein B
  • C-Reactive Protein, Cardiac
  • Ferritin
  • Alb/Creat Ratio, Urine
  • Alkaline Phosphatase
  • FSH
  • T4,Free(Direct)

Biomarkers · Chemical

Arsenic, Urine

LOINC codes
13463-5, 21074-0
Tests that measure Arsenic, Urine
Quest Diagnostics 9

Ranges

Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ

Quest Diagnostics, Comprehensive Toxic Metal Panel, 24-Hour Urine 37081

PopulationInterval
Arsenic, 24-Hour Urine≤80 mcg/L |
Lead, 24-Hour Urine<80 mcg/L |
Mercury, 24-Hour Urine≤20 mcg/L | Toxic: ≥150 mcg/L
Cadmium, 24-Hour Urine≤5.0 mcg/L |
Cobalt, 24-Hour Urine≤2.0 mcg/L |
Thallium, 24-Hour Urine≤2 mcg/L | Toxic: >200 mcg/L

Quest Diagnostics test catalog, 37081

Quest Diagnostics, Heavy Metals Panel with Cadmium, 24-Hour Urine 35386

PopulationInterval
Arsenic, 24-Hour Urine≤80 mcg/L
Lead, 24-Hour Urine<80 mcg/L
Mercury, 24-Hour Urine≤20 mcg/L
Cadmium, 24-Hour Urine≤5.0 mcg/L

Quest Diagnostics test catalog, 35386

Quest Diagnostics, Heavy Metals Panel, 24-Hour Urine 36438

PopulationInterval
Arsenic, 24-Hour Urine≤80 mcg/L
Lead, 24-Hour Urine<80 mcg/L
Mercury, 24-Hour Urine≤20 mcg/L

Quest Diagnostics test catalog, 36438

Tests

Check the catalog code, specimen, method and preparation for every test that measures Arsenic, Urine. Select up to five tests to compare them side by side.

Quest Diagnostics 9 tests

Single-analyte tests

  • Arsenic, 24-Hour Urine 36433

    Urine · Fasting not stated · Turnaround Set up: Tues, Thurs, Sat

    Method and collection
    Method
    Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
    Preparation
    Avoid seafood consumption for 48 hours prior to collection
    Collection
    Avoid worksite collection. Collect urine in an acid-washed or metal-free plastic container.
    Reference notes
    ≤80 mcg/L
    Quest Diagnostics catalog page

Panels that include this biomarker

  • Heavy Metals Panel, 24-Hour Urine 36438

    3 analytes · Urine · Fasting not stated

    Method and collection
    Method
    Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
    Preparation
    Avoid seafood consumption for 48 hours prior to collection
    Collection
    Avoid worksite collection. Collect urine in an acid-washed or metal-free plastic container.
    Quest Diagnostics catalog page
  • Heavy Metals Panel with Cadmium, 24-Hour Urine 35386

    4 analytes · Urine · Fasting not stated

    Method and collection
    Method
    Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
    Preparation
    Avoid seafood consumption for 48 hours prior to collection
    Collection
    Avoid worksite collection. Collect urine in an acid-washed or metal-free plastic container.
    Quest Diagnostics catalog page
  • Heavy Metals Panel, Random Urine 7507

    4 analytes · Urine · Fasting not stated

    Method and collection
    Method
    Colorimetric (C) • Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
    Preparation
    Avoid seafood consumption for 48 hours prior to collection
    Collection
    Avoid worksite collection. Collect urine in an acid-washed or metal-free plastic container.
    Reference notes
    See individual tests
    Quest Diagnostics catalog page
  • Heavy Metals Panel with Cadmium, Random Urine 15110

    5 analytes · Urine · Fasting not stated

    Method and collection
    Method
    Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
    Preparation
    Avoid seafood consumption for 48 hours prior to collection
    Collection
    Avoid worksite collection. Collect urine in an acid-washed or metal-free plastic container.
    Reference notes
    See individual tests
    Quest Diagnostics catalog page
  • Comprehensive Toxic Metal Panel, 24-Hour Urine 37081

    6 analytes · Urine · Fasting not stated

    Method and collection
    Method
    Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
    Preparation
    Avoid seafood consumption for 48 hours prior to collection
    Collection
    Avoid worksite collection. Collect urine in an acid-washed or metal-free plastic container. Tests performed on a specimen submitted in a non-trace element tube or non acid-washed/non metal-free container may not accurately reflect the patient's level. If a non-trace element tube/container is received, it will be accepted for testing. However, elevated results shall be reported with a message that a re-submission with a trace element tube/container is recommended.
    Quest Diagnostics catalog page

0 of 5 tests selected

Pick one more

Sources

Verify these ranges and sources

We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.

Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.