Biomarkers · Chemical
Plasminogen Act Inhibitor-1,Ag
- Primary unit
- ng/mL
- LOINC codes
- 22758-7
- Tests that measure Plasminogen Act Inhibitor-1,Ag
- Quest Diagnostics 2, Labcorp 1
Tests
Check the catalog code, specimen, method and preparation for every test that measures Plasminogen Act Inhibitor-1,Ag. Select up to five tests to compare them side by side.
Quest Diagnostics 2 tests
Single-analyte tests
Plasminogen Activator Inhibitor (PAI-1) Ag 36555
Plasma · Fasting not stated · Turnaround Set up: Tues (p.m.); Report available: 5 days
Quest Diagnostics catalog pageMethod and collection
- Method
- Enzyme Immunoassay (EIA)
- Reference notes
- 4-43 ng/mL
Panels that include this biomarker
Fibrinolysis Comprehensive Panel 90923
9 analytes · Plasma · Fasting required
Quest Diagnostics catalog pageMethod and collection
- Method
- Chromogenic Assay • Clot Dissolution • Hemagglutination (HA) • Immunoassay (IA) • Latex Agglutination (LA)
- Preparation
- Morning fasting is required. Since lipemia may interfere with clotting endpoint detection, a two-hour fast is recommended.
- Collection
- Please submit a separate, frozen vial for each special coagulation assay ordered. Draw blood in a light blue-top tube containing 3.2% sodium citrate, mix gently by inverting 3-4 times. Centrifuge 15 minutes at 1500 g within one hour of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial(s). Freeze immediately and transport on dry ice. To avoid release of plasminogen activator, do not massage vein vigorously, pump fist excessively or leave tourniquet in place for a prolonged period. Centrifuge within 30 minutes after collection to get platelet-poor plasma and freeze on dry ice. Prohibit exercise prior to drawing sample.
- Reference notes
- See Laboratory Report
Labcorp 1 test
Single-analyte tests
Plasminogen Act Inhibitor-1,Ag 146790
Plasma · Fasting not stated · Turnaround 4 - 7 days
Labcorp catalog pageMethod and collection
- Method
- Enzyme-linked immunosorbent assay (ELISA)
- Collection
- Citrated plasma samples should be collected by double centrifugation. Platelet-poor plasma is needed. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a LabCorp PP transpak frozen purple tube with screw cap (LabCorp No. 49482). Freeze immediately and maintain frozen until tested. Print and use the Specimen Collection Bulletin as a tube-filling guide.
0 of 5 tests selected
Pick one moreSources
1 test: codes, specimens, methods, preparation and reference intervals.
Quest Diagnostics test catalog
2 tests: codes, specimens, methods, preparation and reference intervals.
LOINC 22758-7
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for Plasminogen Act Inhibitor-1,Ag
Registered studies that measure Plasminogen Act Inhibitor-1,Ag, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.