Biomarker Lens

Common biomarkers

  • Hemoglobin
  • Glucose
  • ALT
  • Apolipoprotein B
  • C-Reactive Protein, Cardiac
  • Ferritin
  • Alb/Creat Ratio, Urine
  • Alkaline Phosphatase
  • FSH
  • T4,Free(Direct)

Biomarkers · Chemical

Rubella Antibodies, IgG

Primary unit
index
LOINC codes
5334-8
Tests that measure Rubella Antibodies, IgG
Labcorp 6, Quest Diagnostics 2

Ranges

Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ

Quest Diagnostics, Rubella Antibody (IgG), Immune Status 802

PopulationInterval
IndexInterpretation
<0.90Not consistent with immunity
0.90-0.99Equivocal
≥1.00Consistent with immunity

Quest Diagnostics test catalog, 802

Tests

Check the catalog code, specimen, method and preparation for every test that measures Rubella Antibodies, IgG. Select up to five tests to compare them side by side.

Labcorp 6 tests

Single-analyte tests

  • Rubella Antibodies, IgG 006197

    Serum · Fasting not stated · Turnaround 1 - 2 days

    Method and collection
    Method
    Chemiluminescent immunoassay (CLIA)
    Reference notes
    • Nonimmune: <0.90 index • Equivocal: 0.90−0.99 index • Immune: >0.99 index
    Labcorp catalog page

Panels that include this biomarker

  • Measles, Mumps, Rubella (MMR) Immunity Profile 058495

    3 analytes · Serum · Fasting not stated · Turnaround 1 - 2 days

    Method and collection
    Method
    See individual tests.
    Reference notes
    See individual tests.
    Labcorp catalog page
  • Prenatal Infectious Disease Antibodies, Qualitative, IgG 164101

    5 analytes · Serum · Fasting not stated · Turnaround 1 - 3 days

    Method and collection
    Method
    Chemiluminescent immunoassay (CLIA)
    Labcorp catalog page
  • Pregnancy, Initial Screening Profile 144053

    39 analytes · Serum · Fasting not stated · Turnaround 1 - 4 days

    Method and collection
    Method
    See individual test components.
    Collection
    Serum specimen: Usual blood collection technique. Urine (urinalysis and culture): A voided specimen is usually suitable. If the specimen is likely to be contaminated, a clean catch midstream specimen is desirable. Lavender-top (EDTA): Gently invert lavender top tubes 8-10 times immediately to mix specimen with anticoagulant. Ct/GC: Option 1: Gen-Probe® Aptima® endocervical or vaginal swab. Endocervical swab: Remove excess mucus from the cervical os and surrounding mucosa using the cleaning swab (white-shaft swab in the package with red printing). Discard this swab. Insert the specimen collection swab (blue-shaft swab in the package with green printing) into the endocervical canal. Gently rotate the swab clockwise for 10 to 30 seconds in the endocervical canal to ensure adequate sampling. Withdraw the swab carefully; avoid contact with the vaginal mucosa. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of the contents. Recap the swab specimen transport tube tightly. Vaginal Swab: Care Provider Specimen: Collect vaginal fluid sample using the Gen-Probe® Aptima® vaginal swab kit by contacting the swab to the lower third of the vaginal wall and rotating the swab for 10 to 30 seconds to absorb fluid. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Patient Self-Collection: Partially open the package of the Gen-Probe® Aptima® vaginal swab kit. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima® swab specimen collection kit. Remove the swab. Carefully insert the swab into the vagina about two inches past the introitus and gently rotate the swab for 10 to 30 seconds, making sure the swab touches the walls of the vagina so that moisture is absorbed by the swab. Withdraw the swab without touching the skin. Immediately place the swab into the transport tube, and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Ct/GC: Option 2: Urine Specimen: The patient should not have urinated for at least one hour prior to specimen collection. Direct patient to provide a first-catch urine (approximately 20 to 30 mL of the initial urine stream) into a urine collection cup free of any preservatives. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity; lesser volumes may not adequately rinse organisms into the specimen. Female patients should not cleanse the labial area prior to providing the specimen. Add urine to the Aptima® Combo 2 urine collection device. The final volume must be between the two black lines on the device (about 2 mL).
    Labcorp catalog page
  • Pregnancy, Initial Screening Profile With HBV Triple Panel 144059

    41 analytes · Serum · Fasting not stated · Turnaround 1 - 4 days

    Method and collection
    Method
    See individual test components.
    Collection
    Serum specimen: Usual blood collection technique. Urine (urinalysis and culture): A voided specimen is usually suitable. If the specimen is likely to be contaminated, a clean catch midstream specimen is desirable. Lavender top (EDTA): Gently invert lavender-top tubes eight to 10 times immediately to mix specimen with anticoagulant. Ct/GC: Option 1: Gen-Probe® Aptima® endocervical or vaginal swab Endocervical swab: Remove excess mucus from the cervical os and surrounding mucosa using the cleaning swab (white-shaft swab in the package with red printing). Discard this swab. Insert the specimen collection swab (blue-shaft swab in the package with green printing) into the endocervical canal. Gently rotate the swab clockwise for 10 to 30 seconds in the endocervical canal to ensure adequate sampling. Withdraw the swab carefully; avoid contact with the vaginal mucosa. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of the contents. Recap the swab specimen transport tube tightly. Vaginal Swab: Care provider specimen: Collect vaginal fluid sample using the Gen-Probe® Aptima® vaginal swab kit by contacting the swab to the lower third of the vaginal wall and rotating the swab for 10 to 30 seconds to absorb fluid. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Patient self-collection: Partially open the package of the Gen-Probe® Aptima® vaginal swab kit. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima® swab specimen collection kit. Remove the swab. Carefully insert the swab into the vagina about two inches past the introitus and gently rotate the swab for 10 to 30 seconds, making sure the swab touches the walls of the vagina so that moisture is absorbed by the swab. Withdraw the swab without touching the skin. Immediately place the swab into the transport tube, and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Option 2 (urine specimen): The patient should not have urinated for at least one hour prior to specimen collection. Direct patient to provide a first-catch urine (approximately 20 to 30 mL of the initial urine stream) into a urine collection cup free of any preservatives. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity; lesser volumes may not adequately rinse organisms into the specimen. Female patients should not cleanse the labial area prior to providing the specimen. Add urine to the Aptima® Combo 2 urine collection device. The final volume must be between the two black lines on the device (about 2 mL).
    Labcorp catalog page
  • Pregnancy, Initial Screening Profile With HBV Triple Panel, VZV Immunity and QuantiFERON®-TB Gold Plus 144099

    42 analytes · Serum · Fasting not stated · Turnaround 1 - 4 days

    Method and collection
    Method
    See individual test components.
    Collection
    Serum specimen: Usual blood collection technique Urine (urinalysis and culture): A voided specimen is usually suitable. If the specimen is likely to be contaminated, a clean catch midstream specimen is desirable. Lavender top (EDTA): Gently invert lavender-top tubes eight to 10 times immediately to mix specimen with anticoagulant. Ct/GC: Option 1: Gen-Probe® Aptima® endocervical or vaginal swab Endocervical swab: Remove excess mucus from the cervical os and surrounding mucosa using the cleaning swab (white-shaft swab in the package with red printing). Discard this swab. Insert the specimen collection swab (blue-shaft swab in the package with green printing) into the endocervical canal. Gently rotate the swab clockwise for 10 to 30 seconds in the endocervical canal to ensure adequate sampling. Withdraw the swab carefully; avoid contact with the vaginal mucosa. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of the contents. Recap the swab specimen transport tube tightly. Vaginal Swab: Care provider specimen: Collect vaginal fluid sample using the Gen-Probe® Aptima® vaginal swab kit by contacting the swab to the lower third of the vaginal wall and rotating the swab for 10 to 30 seconds to absorb fluid. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Patient self-collection: Partially open the package of the Gen-Probe® Aptima® vaginal swab kit. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima® swab specimen collection kit. Remove the swab. Carefully insert the swab into the vagina about two inches past the introitus and gently rotate the swab for 10 to 30 seconds, making sure the swab touches the walls of the vagina so that moisture is absorbed by the swab. Withdraw the swab without touching the skin. Immediately place the swab into the transport tube, and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Option 2 (urine specimen): The patient should not have urinated for at least one hour prior to specimen collection. Direct patient to provide a first-catch urine (approximately 20 to 30 mL of the initial urine stream) into a urine collection cup free of any preservatives. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity; lesser volumes may not adequately rinse organisms into the specimen. Female patients should not cleanse the labial area prior to providing the specimen. Add urine to the Aptima® Combo 2 urine collection device. The final volume must be between the two black lines on the device (about 2 mL). QuantiFERON-TB Gold Plus Kit: The QuantiFERON-TB Gold Plus collection kit contains the instructions for the collection and handling of (one each): (1) gray-top (with white ring), uncoated (nil); (2) green cap with white ring, TB1 tube; (3) yellow cap with white ring, TB2 tube; (4) purple top with white ring, mitogen-coated. A high-altitude kit is also available for locations between 3350 and 6150 feet; a cap with a yellow ring differentiates the tubes. Blood collection tubes should be at room temperature at the time of collection. Refer to collection instructions included with draw kit. Special specimen collection kit contains four gel-barrier tubes as noted above. All four tubes are required for a single test result. Each tube is designed to draw only 1 mL and fill time may be longer than other blood collection tubes. Because of the limited vacuum in these tubes, use a needle and holder (not a butterfly) to collect QuantiFERON specimens. If a butterfly is required, first collect other required tubes or use another Vacutainer tube to purge the butterfly line of air and then proceed with drawing the QuantiFERON tubes. Fill tubes to the black fill line on the tube. If tubes are underfilled or overfilled (see kit insert), immediately collect a replacement tube. Following proper fill, label the tubes appropriately and shake tubes 10 times firmly enough to ensure the entire surface of the tube is coated with blood cells to solubilize the antigen on the tube walls. After shaking, the volume may fall below the fill line. Do not centrifuge or refrigerate specimens. Return each of the four properly filled, labeled, and shaken tubes to the box labeled "QFT kit." Seal the top by removing tape from the adhesive. To preserve cellular viability, specimens should be collected and sent the same day, at room temperature, so as to arrive at the lab as soon as possible and within 14 hours of collection.
    Labcorp catalog page

Quest Diagnostics 2 tests

Single-analyte tests

  • Rubella Antibody (IgG), Immune Status 802

    Serum · Fasting not stated · Turnaround Set up: Mon-Fri; Report available: 4 days

    Method and collection
    Method
    Immunoassay (IA)
    Quest Diagnostics catalog page

Panels that include this biomarker

  • Rubella Antibodies (IgG, IgM) Diagnostic 37673

    2 analytes · Serum · Fasting not stated

    Method and collection
    Method
    Immunoassay (IA)
    Reference notes
    See Laboratory Report
    Quest Diagnostics catalog page

0 of 5 tests selected

Pick one more

Sources

Verify these ranges and sources

We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.

Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.

Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.