Biomarkers · Chemical
Mercury, Urine
- Primary unit
- ug/L
- LOINC codes
- 21383-5, 5689-5
- Tests that measure Mercury, Urine
- Quest Diagnostics 7, Labcorp 4
Ranges
Each lab publishes a reference range for the population groups it tests, usually the middle 95% of results. These intervals describe that population, not an optimal or healthy target. How ranges differ
Quest Diagnostics, Mercury, 24-Hour Urine 36441
| Population | Interval |
|---|---|
| Reference Range | ≤20 mcg/L |
| Toxic | ≥150 mcg/L |
Tests
Check the catalog code, specimen, method and preparation for every test that measures Mercury, Urine. Select up to five tests to compare them side by side.
Quest Diagnostics 7 tests
Single-analyte tests
Mercury, 24-Hour Urine 36441
Urine · Fasting not stated · Turnaround Set up: Tues, Thurs, Sat
Quest Diagnostics catalog pageMethod and collection
- Method
- Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
- Preparation
- Avoid seafood consumption for 48 hours prior to collection
- Collection
- Avoid worksite collection. Collect urine in an acid-washed or metal-free plastic container.
Panels that include this biomarker
Heavy Metals Panel, 24-Hour Urine 36438
3 analytes · Urine · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
- Preparation
- Avoid seafood consumption for 48 hours prior to collection
- Collection
- Avoid worksite collection. Collect urine in an acid-washed or metal-free plastic container.
- Reference notes
- Arsenic, 24-Hour Urine | ≤80 mcg/L Lead, 24-Hour Urine | <80 mcg/L Mercury, 24-Hour Urine | ≤20 mcg/L
Heavy Metals Panel with Cadmium, 24-Hour Urine 35386
4 analytes · Urine · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
- Preparation
- Avoid seafood consumption for 48 hours prior to collection
- Collection
- Avoid worksite collection. Collect urine in an acid-washed or metal-free plastic container.
- Reference notes
- Arsenic, 24-Hour Urine | ≤80 mcg/L Lead, 24-Hour Urine | <80 mcg/L Mercury, 24-Hour Urine | ≤20 mcg/L Cadmium, 24-Hour Urine | ≤5.0 mcg/L
Metals/Metalloids Panel 1, Urine 30323
4 analytes · Urine · Fasting not stated · Turnaround Set up: Mon-Sat
Quest Diagnostics catalog pageMethod and collection
- Method
- Colorimetry (C) • Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
- Preparation
- Avoid exposure to gadolinium-based contrast media for 48 hours prior to sample collection. Avoid seafood consumption for 48 hours prior to sample collection.
- Collection
- Unpreserved urine should be refrigerated immediately and analyzed within 1 week of collection. Acceptable preservatives include: Trace metal-free hydrochloric acid or nitric acid (0.1 mL of 12M acid/10 mL urine).
- Reference notes
- See Laboratory Report
Comprehensive Toxic Metal Panel, 24-Hour Urine 37081
6 analytes · Urine · Fasting not stated
Quest Diagnostics catalog pageMethod and collection
- Method
- Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
- Preparation
- Avoid seafood consumption for 48 hours prior to collection
- Collection
- Avoid worksite collection. Collect urine in an acid-washed or metal-free plastic container. Tests performed on a specimen submitted in a non-trace element tube or non acid-washed/non metal-free container may not accurately reflect the patient's level. If a non-trace element tube/container is received, it will be accepted for testing. However, elevated results shall be reported with a message that a re-submission with a trace element tube/container is recommended.
- Reference notes
- Arsenic, 24-Hour Urine | ≤80 mcg/L Lead, 24-Hour Urine | <80 mcg/L Mercury, 24-Hour Urine | ≤20 mcg/L | Toxic: ≥150 mcg/L Cadmium, 24-Hour Urine | ≤5.0 mcg/L Cobalt, 24-Hour Urine | ≤2.0 mcg/L Thallium, 24-Hour Urine | ≤2 mcg/L | Toxic: >200 mcg/L
Heavy Metals Panel 4, Urine (CSA) 34695
8 analytes · Urine · Fasting not stated · Turnaround Set up: Mon, Tues, Thurs; Report available: 7 days
Quest Diagnostics catalog pageMethod and collection
- Method
- Colorimetry (C) • Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
- Preparation
- Avoid exposure to gadolinium-based contrast media for 48 hours prior to sample collection. Avoid seafood consumption for 48 hours prior to sample collection.
- Collection
- Unpreserved urine should be refrigerated immediately and analyzed within 1 week of collection. Acceptable preservatives include: Trace metal-free hydrochloric acid or nitric acid (0.1 mL of 12M acid/10 mL urine).
- Reference notes
- See Laboratory Report
Labcorp 4 tests
Panels that include this biomarker
Mercury, Urine 007773
4 analytes · Urine · Fasting not stated · Turnaround 2 - 5 days
Labcorp catalog pageMethod and collection
- Method
- Inductively-coupled plasma/mass spectrometry (ICP/MS)
- Collection
- Sampling time is preshift (meaning 16 hours without exposure). Optional protocol: Instruct the patient to void at 8 AM and discard the specimen. Then collect all urine including the final specimen voided at the end of the 24-hour collection period (ie, 8 AM the next morning). Screw the lid on securely. Mix well.
- Reference notes
- • Environmental exposure: <5.0 μg/g creatinine, <20.0 μg/L • Occupational exposure: BEI® (inorganic mercury, sampling time is preshift): 20 μg/g creatinine1
Heavy Metals Profile I, Urine 007046
9 analytes · Urine · Fasting not stated · Turnaround 3 - 6 days
Labcorp catalog pageMethod and collection
- Method
- Inductively coupled plasma-mass spectrometry (ICP-MS)
- Preparation
- Patient should avoid seafood and red wine 72 hours prior to collection.
- Collection
- Sampling time is not critical for industrial monitoring. Optional protocol : Instruct the patient to void at 8 AM and discard the specimen. Then collect all urine including the final specimen voided at the end of the 24-hour collection period (ie, 8 AM the next morning). Avoid contact with metal during collection. Screw the lid on securely. See individual tests for collection times for industrial monitoring.
Heavy Metals Profile II, Urine 250281
12 analytes · Urine · Fasting not stated · Turnaround 3 - 6 days
Labcorp catalog pageMethod and collection
- Method
- Inductively-coupled plasma/mass spectrometry (ICP/MS)
- Preparation
- Patient should avoid seafood and red wine 72 hours prior to collection.
- Collection
- Optional protocol : Instruct the patient to void at 8 AM and discard the specimen. Then collect all urine including the final specimen voided at the end of the 24-hour collection period (ie, 8 AM the next morning). Avoid contact with metal during collection. Screw the lid on securely. See individual tests for collection times for industrial monitoring.
- Reference notes
- See individual tests.
Common Alloy Elements Profile 007069
21 analytes · Urine · Fasting not stated · Turnaround 3 - 5 days
Labcorp catalog pageMethod and collection
- Method
- Inductively-coupled plasma-mass spectrometry (ICP/MS)
- Preparation
- Patient must avoid seafood and red wine 72 hours prior to collection.
- Collection
- Collect 24-hour urine without preservatives. Mix well.
0 of 5 tests selected
Pick one moreSources
4 tests: codes, specimens, methods, preparation and reference intervals.
Quest Diagnostics test catalog
7 tests: codes, specimens, methods, preparation and reference intervals.
Regenstrief Institute codes that identify the same result across labs.
Search ClinicalTrials.gov for Mercury, Urine
Registered studies that measure Mercury, Urine, on the U.S. National Library of Medicine registry.
Verify these ranges and sources
We compile this page from named laboratory catalogs, guidelines and studies. Labs calculate reference intervals from the people they test, for one assay method and one population group, so an interval describes that population rather than an optimal target.
Interpret your own results with a licensed clinician, or track your lab history and health goals in Aumnivida.
Spotted an error? Email hello@biomarkerlens.com with the page URL and the primary source that corrects the entry.